PCB-(M)350C23
    zoom_out_map

      PCB-(M)350C23

    • ICP® shock acceleration sensor,
    • Masseisoliert,
    • With electric and mechanical filter,
    • Measuring range 10,000 g,
    • Frequency range 0.4 … 10,000 Hz,
    • Integrated cable, length 3 m,
      ending on 10-32 plug
    • basic data
      sensitivity (±30%)0.5 mV / g0.05 mV/(m/s²)
      range±10. 000 g pk±98. 000 m / pk
      Frequency range (± 1 dB)0.4 … 10,000 Hz
      frequency range (-3 dB)0.2 … 25,000 Hz[4]
      Corner frequency of the electrical filter (-3 dB)21,000 Hz[2] [1]
      resonance frequency of the mechanical filter35,000 Hz[3] [1]
      Resonance frequency≥ 100,000 Hz
      wide band resolution (1 … 10,000 Hz)0.39 m/s² rmsrms 0.04 g[1]
      Linearity error≤ 2.0%
      transverse acceleration sensitivity≤ 7%
      conditions
      Overload limit ( Shock)±50. 000 g pk±490. 000 m / pk
      temperature range (operation)0 … 150 ° F-18 … 66 ° C
      Temperature range(Storage)-40 …200 °F-40 … 93 ° C
      Temperature influencediagram below[1]
      strain sensitivity (footprint)0,002 g/µε0.02 (m/s²) /. µ ε[1]
      specifications
      power supply20 … 30 V DC
      Constant power supply2 … 20 mA
      Output impedance≤200Ω
      Bias voltage8 … 14 V DC
      Discharging charging time constant1.0 … 2.0 s[1]
      settling time (area within ±10% of the bias voltage)< 10 s
      Electrical insulation> 1 M Ω
      physical properties
      sensor elementceramic
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealedsealedclose
      size - hex0.375 in9.5 mm
      size - height0.88 in22.4 mm
      Mass0.19 oz5.4 grams[1]
      electrical connectionintegrated cable
      cable10 ft3 m
      cord typetype 031, twisted pair
      mounting thread1/4 "-28 thread
      " Notes
      [1]typically
      [2]second-order low-pass filter
      [3]the amplitude is increased in the resonance frequency by 9 dB.
      [4]the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.
      [5]details: see PCBs Declaration of conformance PS135
      Accessories
      ACS-14Hopkinson barCalibration of shock sensor-1
      ACS-22frequency response, traceable to NIST (100 Hz to ±1dB point)-1
      (M) metric mounting
      Mounting threadM6 x 0.75 male
      PCB-(M)350C23

      Specific References

      Download

      350C23_drawing.PDF

      Technical drawing

      Download (74.88k)

      350C23_manual.PDF

      Operating instructions

      Download (1.71M)

      350C23_specs.PDF

      Technical data sheet

      Download (75.08k)