PCB-(M)350C04
zoom_out_map

PCB-(M)350C04

  • ICP® shock acceleration sensor,
  • With electric and mechanical filter,
  • Measuring range 5,000 g,
  • Sensitivity 1 mV / g,
  • Frequency range 0.4 … 10,000 Hz,
  • 10-32 female connector above
  • basic data
    sensitivity (±30%) 1.0 mV / g 0.10 mV/(m/s²)  
     
    range ±5. 000 g pk ±49. 000 m / pk  
     
    Frequency range (± 1 dB) 0.4 … 10,000 Hz    
     
    frequency range (-3 dB) 0.2 … 25,000 Hz   [4]
     
    Corner frequency of the electrical filter (-3 dB) 21,000 Hz   [2] [1]
     
    resonance frequency of the mechanical filter 35,000 Hz   [3] [1]
     
    Resonance frequency ≥ 100,000 Hz    
     
    wide band resolution (1 … 10,000 Hz) 0.20 m/s² rms rms 0.02 g [1]
     
    Linearity error ≤ 2.0%    
     
    transverse acceleration sensitivity ≤ 7%    
    conditions
    Overload limit (Shock) ±50. 000 g pk ±490. 000 m / pk  
     
    temperature range (operation) 0 … 150 ° F -18 … 66 ° C  
     
    Temperature range(Storage) -40 …200 °F -40 … 93 ° C  
     
    Temperature influence See graph %/°F    
     
    strain sensitivity (footprint) 0,002 g/µε 0.02 (m/s²) /µε [1]
    specifications
    power supply 20 … 30 V DC    
     
    Constant power supply 2 … 20 mA    
     
    Output impedance ≤200Ω    
     
    Bias voltage 8 … 14 V DC    
     
    Discharging charging time constant 1.0 … 2.0 s   [1]
     
    settling time (area within ±10% of the bias voltage) < 10 s    
    Physical properties
    sensor element ceramic    
     
    geometry of the sensor element shear principle    
     
    Housing material titanium    
     
    sealing hermetic    
     
    Size - hex 0.375 in 9.5 mm  
     
    size - height 1.15 in 29.2 mm  
     
    Mass 0.19 oz 5.4 grams [1]
     
    Electrical connection 10-32-coaxial socket    
     
    connection top    
     
    mounting thread 1/4 '28 External thread    
    notes
    [1] typically    
     
    [2] second-order low-pass filter    
     
    [3] the amplitude is increased in the resonance frequency by 9 dB.    
     
    [4] the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.    
     
    [5] details: see PCBs Declaration of conformance PS023    
    Accessories
    ACS-14 Hopkinson bar calibration f for shock sensor -1  
     
    ACS-22 frequency response,.traceable to NIST (100 Hz to ±1dB point) -1  
    (M) metric mounting
    mounting thread M6 x 0.75 male    
    (W)-waterproof Cable
    electrical connection integrated cord with waterproof connection    
    PCB-(M)350C04

    Specific References

    Download

    350C04_drawing.PDF

    Technical drawing

    Download (92.6k)

    350C04_manual.PDF

    Operating instructions

    Download (1.73M)

    350C04_specs.PDF

    Technical data sheet

    Download (83.13k)