PCB-(M)350B01
zoom_out_map

PCB-(M)350B01

  • ICP® shock acceleration sensor,
  • Masseisoliert,
  • With electric and mechanical filter,
  • Measuring range 100,000 g,
  • Sensitivity 0.05 mV / g,
  • Frequency range 4 … 10,000 Hz,
  • Integrated cable, length 3 m,
    ending on 10-32 plug
  • basic data
    sensitivity (±30%) /0.05 mV / g 0.005 mV/(m/s²)
    range ±100. 000 g pk ±981. 000 m/s² PK
    frequency range (± 1 dB) 4 … 10,000 Hz
    frequency range (-3 dB) 2 … 25,000 Hz [4]
    Corner frequency of the electrical filter (-3 dB) 21,000 Hz [2] [1]
    resonance frequency of the mechanical filter 35,000 Hz [3] [1]
    Resonance frequency ≥ 100,000 Hz
    wide band resolution (1 … 10,000 Hz) rms 4.9 m/s 2 0.5 g rms [1]
    Linearity error (per 10,000 g / 9≥ 100 MΩs²) ≤ 2.5%
    transverse acceleration sensitivity ≤ 7%
    conditions of use
    (Shock) overload limit 150.000 g pk ±1. 471.500 m / pk
    temperature range (operation) 0 … 150 ° F -18 … 66 ° C
    Temperature range (storage) -40 …200 °F -40 … 93 ° C
    specifications
    power supply 20 … 30 V DC
    Constant power supply 2 … 20 mA
    output impedance ≤200Ω
    Bias voltage 8 … 14 V DC
    Discharging charging time constant 0.10 s [1]
    settling time (on area within ±10% of the bias voltage) < 1s
    Electrical insulation (housing) > 1 M Ω
    physical properties
    sensor element ceramic
    Geometry of the sensor element shear principle
    housing material titanium
    sealed sealed close
    size - hex 0.375 in 9.5 mm
    Size - height 1.04 in 26.5 mm
    dimensions (without cable) 0.20 oz 5.5 grams [1]
    electrical connection Integrated cable
    cable length 10 ft 3 m
    cord type type 031, twisted pair
    Mounting thread 1/4 "-28 thread
    Assembly torque 25 … 35 in-lb 280 … 390 NCM
    notes"
    [1] typically
    [2] second-order low-pass filter
    [3] is the amplitude in the range Resonant frequency increased by 9 dB.
    [4] the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.
    [5] has been tested on a Shaker at 100 Hz
    Accessories
    ACS-22 frequency response, traceable to NIST (100 Hz ±1dB point) -1
    PCB-(M)350B01

    Specific References

    Download

    350B01_drawing.PDF

    Technical drawing