PCB-350A43
    zoom_out_map

      PCB-350A43

      • Triaxial ICP® shock acceleration sensor,
      • Mass-insulated,
      • With electric and mechanical filters,
        (-3 dB at 25,000 Hz)
      • Measuring range 10,000 g,
      • Sensitivity 0.5 mV / g,
      • Frequency range 0.4... 10,000 Hz,
      • Integrated cable, length 1.5 m,
        ending on 4-pin female connector,
      • Including extension cable, length 1.5 m,
        ending on three BNC plugs
      Specifications
      Basic dataEnglish unitsSI units 
      Sensitivity (± 30 %)0.5 mV / g0.05 mV/(m/s²) 
      Measuring range±10.000 gPK±98.000 m/s²PK 
      Frequency range (± 1 dB)0.4... 10,000 Hz 
      Frequency range (-3 dB)0.2... 25,000 Hz[2]
      Resonance frequency≥50.000 Hz 
      Electrical filter corner frequency
      (-3 dB)
      21,000 Hz[3] [1]
      Resonance frequency of the mechanical filter35,000 Hz[4] [1]
      Wide band resolution (1... 10,000 Hz)0.04 gRMS0.39 m/s² RMS[1]
      Linearity error≤2%  
      Transverse acceleration sensitivity≤7%  
      Conditions of use
      Overload limit (shock)±50. 000 g pk±490. 000 m/s² pk 
      temperature range (operation)0... 150 ° F18... 66 ° C 
      temperature range (storage)40...200 °F40... 93 ° C 
      strain sensitivity (footprint)0,002 g/µε0.02 (m/s²)/µε[1]
      specifications
      power supply20... 30 V DC 
      constant power supply2... 20 mA 
      output impedance≤200Ω 
      Bias voltage8... 14 V DC 
      discharging charging time constant1.0... 2.0 s[1]
      settling time
      (auf Bias-Spannung ±10 %)
      < 10 s 
      electrical insulation (base)≥100 MΩ 
      physical Properties
      sensor elementceramic 
      geometry of the sensor elementshear principle 
      housing materialtitanium 
      SealingHermetic 
      Size - height1.02 in26.0 mm 
      Size - length1.02 in26.0 mm 
      Size - width1.02 in26.0 mm 
      Weight (without cable)2.2 oz62.5 grams[1]
      Electrical connectionIntegrated cable 
      Cable outletOn the side 
      Cable termination4-pin connector (1/4 "28") 
      Cable length5.0 ft1.52 m 
      Cable typeType 034, 4-conductor shielded cable 
      FixingThrough-holes 
      Notes
      [1]Typically  
      [2]The specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.  
      [3]Second-order low-pass filter  
      [4]The amplitude is increased in the resonance frequency by 9 dB.  
      [5]Details: See PCBs Declaration of conformance PS023  
      Included accessories
      034 G 054-wire shielded cable, length 1.5 m, 4-pin connector to three BNC(1)
      080A197Mounting plate for the model 350 B 50(1)
      100-15136-80Mounting screw M6 x 1.0(2)
      100-8360-70Mounting screw 1/4 '28(2)
      100-8994-40Grease(1)
      ACS-14THopkinson bar calibration for shock resistance thermometer(1)
      ACS-22TFrequency response for Triaxial accelerometer, traceable to NIST (100 Hz to the upper ±1dB point < / td)>(1)
      PCB-350A43

      Specific References

      Download

      350A43_specs.PDF

      350A43_specs

      Download (76.03k)

      350A43_drawing.PDF

      350A43_drawing

      Download (111.89k)