PCB-350A43
zoom_out_map

PCB-350A43

  • Triaxial ICP® shock acceleration sensor,
  • Mass-insulated,
  • With electric and mechanical filters,
    (-3 dB at 25,000 Hz)
  • Measuring range 10,000 g,
  • Sensitivity 0.5 mV / g,
  • Frequency range 0.4... 10,000 Hz,
  • Integrated cable, length 1.5 m,
    ending on 4-pin female connector,
  • Including extension cable, length 1.5 m,
    ending on three BNC plugs
Specifications
Basic dataEnglish unitsSI units 
Sensitivity (± 30 %) 0.5 mV / g 0.05 mV/(m/s²)  
Measuring range ±10.000 gPK ±98.000 m/s²PK  
Frequency range (± 1 dB) 0.4... 10,000 Hz  
Frequency range (-3 dB) 0.2... 25,000 Hz [2]
Resonance frequency ≥50.000 Hz  
Electrical filter corner frequency
(-3 dB)
21,000 Hz [3] [1]
Resonance frequency of the mechanical filter 35,000 Hz [4] [1]
Wide band resolution (1... 10,000 Hz) 0.04 gRMS 0.39 m/s² RMS [1]
Linearity error ≤2%   
Transverse acceleration sensitivity ≤7%   
Conditions of use
Overload limit (shock) ±50. 000 g pk ±490. 000 m/s² pk  
temperature range (operation) 0... 150 ° F 18... 66 ° C  
temperature range (storage) 40...200 °F 40... 93 ° C  
strain sensitivity (footprint) 0,002 g/µε 0.02 (m/s²)/µε [1]
specifications
power supply 20... 30 V DC  
constant power supply 2... 20 mA  
output impedance ≤200Ω  
Bias voltage 8... 14 V DC  
discharging charging time constant 1.0... 2.0 s [1]
settling time
(auf Bias-Spannung ±10 %)
< 10 s  
electrical insulation (base) ≥100 MΩ  
physical Properties
sensor element ceramic  
geometry of the sensor element shear principle  
housing material titanium  
Sealing Hermetic  
Size - height 1.02 in 26.0 mm  
Size - length 1.02 in 26.0 mm  
Size - width 1.02 in 26.0 mm  
Weight (without cable) 2.2 oz 62.5 grams [1]
Electrical connection Integrated cable  
Cable outlet On the side  
Cable termination 4-pin connector (1/4 "28")  
Cable length 5.0 ft 1.52 m  
Cable type Type 034, 4-conductor shielded cable  
Fixing Through-holes  
Notes
[1] Typically    
[2] The specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.    
[3] Second-order low-pass filter    
[4] The amplitude is increased in the resonance frequency by 9 dB.    
[5] Details: See PCBs Declaration of conformance PS023    
Included accessories
034 G 05 4-wire shielded cable, length 1.5 m, 4-pin connector to three BNC (1)
080A197 Mounting plate for the model 350 B 50 (1)
100-15136-80 Mounting screw M6 x 1.0 (2)
100-8360-70 Mounting screw 1/4 '28 (2)
100-8994-40 Grease (1)
ACS-14T Hopkinson bar calibration for shock resistance thermometer (1)
ACS-22T Frequency response for Triaxial accelerometer, traceable to NIST (100 Hz to the upper ±1dB point < / td)> (1)
PCB-350A43

Specific References

Download

350A43_specs.PDF

350A43_specs

Download (76.03k)

350A43_drawing.PDF

350A43_drawing

Download (111.89k)