PCB-HT352A21/NC
| basic data | |||
| sensitivity (±15%) | 10 mV / g | 1.0 mV/(m/s²) | |
| range | ±500 g pk | ±4. 900 m/s² pk | |
| frequency range (±5%) | 1.0 … 10,000 Hz | ||
| Frequency range (± 10%) | 0.7 … 13,000 Hz | ||
| frequency range (± 3 dB) | 0.3 … 20,000 Hz | ||
| Resonance frequency | ≥ 50,000 Hz | ||
| wide band resolution | 0.004 g RMS | 0.04 m/s² RMS | [2] |
| Linearity | ≤ 1% | [1] | |
| transverse acceleration sensitivity | ≤ 5% | ||
| conditions of use | |||
| (Shock) overload limit | ± 10.000 g pk | ±98. 000 m/s² pk | |
| Temperature range (operation) | -65 … 325 ° F | -54 … 163 ° C | |
| Specifications | |||
| power supply | 18 … 30 V DC | ||
| Constant power supply | 2 … 20 mA | ||
| output impedance | ≤ 300 Ω | ||
| Bias voltage | 7 … 11 V DC | ||
| Discharging charging time constant | 1.0 … 3<5 s | ||
| settling | < 3 s | ||
| spectral Noise (1 Hz) | 800 µg / √ Hz | 7.840 (µm / s ²) / √ Hz | [2] |
| spectral noise (10 Hz) | 250 µg / √ Hz | 2,450 (µm / s ²) / √ Hz | [2 ] |
| Spectral noise (100 Hz) | 60 µg / √ Hz | 590 (µm / s ²) / √ Hz | [2] |
| spectral noise (1,000 Hz) | 50 µg / √ Hz | 490 (µm / s ²) / √ Hz | [2] |
| Spectral noise (10,000 Hz) | 40 µg / & radic; Hz | 392 (µm / s ²) / √ Hz | [2] |
| physical properties | |||
| size - height | 0.14 in | 3.6 mm | |
| dimensions | 0.02 oz | 0.6 grams | [2] |
| sensor element | ceramic | ||
| geometry of the sensor element | shear principle | ||
| Housing material | titanium | ||
| waterproofing | epoxy resin | ||
| size - length | 0.45 in | 11.4 mm | |
| size - width | 0.25 in | 6.4 mm | |
| electrical connection | 3-56 coaxial plug | ||
| Connecting position | side | ||
| Attachment | bonding | ||
| notes | |||
| [1] | zero-based balancing line, determined using the method of least squares | ||
| [2] | typically | ||
| [3] | details: see PCBs Declaration of conformance PS023 | ||
| Accessories | |||
| 039A27 | transfer tool for the models 352A21, 352 C-22, 352A25, 357A09, 357 C-10 | -1 | |
| 080A109 | Mounting wax | -1 | |
| ACS-1 | frequency response, traceable to NIST (10 Hz up to the upper 5% point) | -1 |