PCB-(M)320C20
,
basic data | |||
sensitivity (±10%) | 10 mV / g | 1.02 mV/(m/s²) | |
range | ±500 g pk | ±4. 900 m/s² pk | |
frequency range (±5%) | 2.0 … 5,000 Hz | ||
Frequency range (± 10%) | 1.5 … 10,000 Hz | ||
integrated filter | low-pass | ||
corner frequency of the electrical Filter | 13,000 Hz | [1] | |
edge steepness of the filter | 6 dB/octave | ||
resonance frequency | ≥60.000 Hz | ||
Wide band resolution | 0.006 g RMS | 0.06 m/s² RMS | [1] |
Linearity | ≤1% | [3] | |
transverse acceleration sensitivity | ≤5% | [2] | |
conditions | |||
Overload limit (shock) | ± 10,000 g pk | ±98.100 m/s² pk | |
temperature range (operation) | -100 … 325 ° F | -73 … 163 ° C | |
strain sensitivity (base area) | ≤0.0005 g/µε | ≤0.005 (m/s²)/µε | [1] |
Technical characteristics | |||
power | 18 … 30 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | ≤100 Ω | ||
Bias voltage | 8 … 12 V DC | ||
Discharging charging time constant | 0.25 … 1 s | ||
spectral noise (1 Hz) | 3.200 µg / √Hz | 31.400 (µm / s ²) / √Hz | |
spectral noise (10 Hz) | 600 µg / √Hz | 5.880 (µm / s ²) / √Hz | [1] |
spectral noise (100 Hz) | 100 µg / √Hz | 980(µm / s ²) / √Hz | [1] |
spectral noise (1,000 Hz) | 60 µg / √Hz | 590 (µm / s ²) / √Hz | [1] |
physical properties | |||
Size - height | 0.87 in | 22.1 mm | |
size - hex | 0.38 in | 9.7 mm | |
mass | 0.23 oz | 6.5 grams | [1] |
Sensor element | quartz | ||
geometry of the sensor element | shear principle | ||
housing material | Titanium | ||
sealing | hermetically sealed | ||
electrical connection | 10-32-coaxial socket | ||
Connection position | above | ||
mounting thread | 10-32 male | ||
Assembly torque | 10 … 20 in-lb | 113 … 225 NCM | |
Notes | |||
[1] | typically | ||
[2] | transverse acceleration sensitivity typically ≤ 3% | ||
[3] | zero-based balancing line, determined using the method of least squares | ||
[4] | details: see PCBs Declaration of conformance PS023 | ||
Accessories | |||
080A | adhesive mounting | -1 | |
080A109 | Mount wax | -1 | |
ACS-1 | frequency response, traceable to NIST (10 Hz up to the upper 5% point) | -1 | |
(M) metric mounting | |||
Mounting thread | M6 x 0.75 male | ||
Equipment | |||
M080A | metric adhesive attachment, 0.5 "hex x 0.187" high, M6 x 0.75 through thread | -1 |