PCB-(M)231B
    zoom_out_map

      PCB-(M)231B

    • Force measuring element with charge output,
    • Range 4.448 … 22,240 N,
    • Sensitivity 4.05 pC/N,
    • Upper frequency limit 15,000 Hz,
    • 10-32 female connector on the side
    • basic data
      sensitivity (±15%)18 pC/lb4.047 pC/kN
      measuring range (pressure)≤ 5,000 lb≤ 22,24 kN
      Measuring range (traction)≤ 1,000 lb≤ 4,448 kN
      maximum permissible static load (force)5,500 lb24,47 kN
      Maximum permissible static load (traction)1.200 lb5,338 kN
      Upper frequency limit15,000 Hz[1] [2]
      linearity≤ 1% FS[3]
      conditions of use
      Temperature range100 … 400 ° F73 … 204 ° C
      Temperature coefficient of sensitivity≤0,01 %/°F≤ 0.018 %/°C
      Technical
      capacity≥ 12 pF[4]
      insulation resistance≥ 1,000,000 M Ω
      Physical properties
      Stiffness2 lb/µin0.35 kN/µm[4]
      Size - diameter0, 65 in16.51 mm
      size - height1.25 in31.75 mm
      weight1.1 oz31 grams
      Housing materialstainless steel
      Sealinghermetically sealed
      electrical connection10-32-coaxial socket
      Connector positionOn the side
      Mounting thread1/4 "-28 threadedNo metric equivalent
      notes
      [1]suppose value is determined on the basis of" Solid state Dynamics calculations
      [2]the lower cutoff frequency and the system noise depend on the used signal conditioning electronics.
      [3]zero-based balancing line, determined using the method of least squares
      [4]typically
      (M) metric mounting
      mounting threadNo. English equivalentM6 x 0.75 female
      (P) positive output voltage
      (W) waterproof cable connection
      Cable outletOn the side
      PCB-(M)231B

      Specific References

      Download

      231B_drawing.PDF

      Technical drawing

      Download (73.72k)

      231B_manual.PDF

      Operating instructions

      Download (1.69M)

      231B_specs.PDF

      Technical data sheet

      Download (22.56k)