PCB-(M)102B15
basic data | |||
(±5 V output range) measuring range | 1,379 kPa | ||
usable range (output range ±10 V) | 400 psi | 2.758 kPa | [3] |
sensitivity (± 5 mV/psi) | 25 mV / psi | 3.6 mV / kPa | |
maximum static pressure | 1,000 psi | 6.895 kPa | |
Resolution | 0.001 psi | 0.007 kPa | [1] |
resonance frequency | ≥ 500, 000 Hz | ||
rise time (reflected pressure) | ≤ 1.0 µs | ||
Lower limiting frequency (-5%) | 0.5 Hz | ||
linearity | ≤1.0% FS | [2] | |
Conditions of use | |||
acceleration sensitivity | ≤ 0.002 psi/g | ≤ 0,0014 kPa/(m/s²) | |
temperature range (operation) | -100 … 275 ° F | -73 … 135 ° C | |
Temperature coefficient of sensitivity | ≤ 0.03 %/°F | ≤ 0,054 %/°C | [1] |
maximum temperature shock(for fraction of a second) | 3,000 ° F | 1,650 ° C | |
Maximum shock resistance | 20,000 g pk | 196,000 m/s² pk | |
Technical characteristics | |||
Output polarity (positive pressure) | positive | ||
Discharging charging time constant (at room temperature) | ≥ 1.0 s | ||
supply | 20 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | < 100Ω | ||
Bias voltage | 8 … 14 V DC | ||
electrical insulation | 100 MΩ | ||
-physical Properties | |||
geometry of the sensor element | compression principle | ||
sensor element | quartz | ||
parts usematerial | stainless steel | ||
membrane | INVAR | ||
sealed | sealeddensely welded | ||
electrical connection | 10-32-coaxial socket | ||
mass | 0.41 oz | 11.6 grams | |
Notes | |||
[1] | typically | ||
[2] | zero-based balancing line, determined using the method of least squares | ||
[3] | for output range up to 10 V, the supply voltage must be at least 24 V DC. At low bias voltage of the sensor, no negative output range is usable up to-10 V. | ||
[4] | details: see PCBs Declaration of conformance PS023 | ||
equipment | |||
065A03 | sealing ring, 0.435 "au need x 0,377 "x 0.030" high brass | 3 | |
(M) metric mounting | |||
equipment | |||
065A40 | Seal ring, 0.435 "outside x 0,397" x 0.030 "high brass | 3 | |
(S) stainless steel diaphragm | |||