| specifications | |||
|---|---|---|---|
| basic data | English units | SI units | |
| Nominal microphone diameter | 1/2" | ||
| application | Freifeld | ||
| Sensitivity in the open circuit | 50 mV / Pa | [2] | |
| Sensitivity in open circuit (± 1.5 dB) | -26 dB relative to 1 V / Pa | [2] | |
| Frequency range (± 1 dB) | 7 … 10.000 Hz | ||
| Frequency range (± 2 dB) | 3,75 … 20.000 Hz | ||
| Lower cutoff frequency (3dB) | 1.0 to 3.0 Hz | ||
| inherent noise | <15.5 dB (A) based on 20 μPa | [1] | |
| Dynamic range (for harmonic distortion ≤3%) | > 137 dB based on 20 μPa | [1] | |
| Operating conditions | |||
| Temperature range (operation) | -40 … 176 °F | -40 … 80 °C | |
| Temperature coefficient of sensitivity (+14 to + 158®F (-10 to + 70 ° C)) | 0.005 dB/°F | 0.009 dB/°C | [1][2] |
| Influence by static pressure | -0,013 dB/kPa | [1][2] | |
| Influence by humidity (0 ... 100%, non-condensing) | -0,01 … 0,01 dB/% RH | [2] | |
| Influence by axial vibration (0.1 g, 1 m / s²) | 63 dB based on 20 μPa | [1] | |
| Technical characteristics | |||
| Polarisationsspannung | 0 v | [3] | |
| supply voltage | 20 … 30 VDC | ||
| Constant current supply | 2 ... 20 mA | ||
| Bias voltage | 10 … 14 VDC | ||
| output impedance | <50 Ω | ||
| Maximum output range | ±7 Vpk | ||
| Physical properties | |||
| housing material | Stainless alloy | ||
| pressure equalization | behind | [4] | |
| Electrical connection | BNC-Stecker | ||
| Mounting thread (protective cap) | 0.5 - 60 US | ||
| Size - diameter (with protective cap) | 0,52 in | 13,2 mm | |
| Size - diameter (without cap) | 0,50 in | 12,7 mm | |
| Size - height (with protective cap) | 4,02 in | 102,1 mm | |
| Size - height (without cap) | 3,99 in | 101,2 mm | |
| Mass | 1,87 oz | 53 grams | [1] |


| Hints | |||
|---|---|---|---|
| [1] | typically, | ||
| [2] | Based on 250 Hz | ||
| [3] | prepolarised | ||
| [4] | Bleed through preamplifier. | ||
| included supply | ||
|---|---|---|
| ACS-63 | Calibrate precision condenser microphones and preamplifiers together | (1) |