PCB-355M102

PCB-355M102

  • ICP® high-temperature vibration sensor,
  • Continuous use temperature up to 163 ° C,
  • With through hole,
  • With built-in low-pass filter,
  • Masseisoliert,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 1 … 7,000 Hz,
  • Mounting with M4 screw,
  • 10-32 female connector on the side

basic data
Sensitivity (± 10%)10 mV / g1.02 mV / (m / s)
measuring range± 500 g pk± 4.900 m / s² pk
Frequency range (± 5%)1 ... 7000 Hz
Frequency range (± 10%)0.75 ... 10,000 Hz
Frequency range (± 3 dB)0.35 ... 17,000 Hz
integrated filterFirst order low pass
Corner frequency of the electric filter?17.000 Hz
resonant frequency?35.000 Hz
Broadband resolution (1 ... 10,000 Hz)0.001 g RMS0.01 m / s RMS[1]
linearity error≤1%[3]
Lateral acceleration sensitivity≤5%[2]
Operating conditions
Overload limit (shock)± 5,000 g pk± 49 050 m / s pk
The temperature range (operation)-65 ... 325 ° F-54 ... 163 ° C
Technical characteristics
supply voltage19 ... 30 V DC
Constant current supply2 ... 20 mA
output impedance≤100 Ω
Bias voltage8 ... 12 V DC
discharging0.5 ... 2.0 s
Settling time 
(on the bias voltage ± 10%)
≤10 s
Spectral Noise (1 Hz)440 µg/√Hz4,320 (µm/s²)/√Hz[1]
Spectral noise (10 Hz)135 µg/√Hz1,325 (µm/s²)/√Hz[1]
Spectral noise (100 Hz)35 µg/√Hz345 (µm/s²)/√Hz[1]
Spectral noise (1,000 Hz)10 µg/√Hz98 (µm/s²)/√Hz[1]
Electrical insulation (base)≥100MΩ
physical properties
Size - Height0.40 in10.2 mm
Size - Length0.70 in17.8 mm
Size - Width0.63 in15.9 mm
Dimensions0.29 oz8.2 grams[1]
sensor elementquartz
Geometry of the sensor elementshear principle
housing materialtitanium
sealhermetically sealed
electrical connection10-32 coaxial
connectionLaterally
attachmentThrough Hole
Hints
[1]typically,
[2]Lateral acceleration sensitivity typically ≤ 3%
[3]Zero-based line of best fit, determined by the method of least squares
[4]Details: see PCB Declaration of Conformance PS023
included supply
081M252Insulated M4 mounting screw (for the model 355M102)-1
M039A22Allen key-1
080A109mounting wax-1
ACS-1Frequency response, traceable to NIST (10 Hz up to the top 5% point)-1