PCB-(M)641B61
| basic data | |||
| range | 0,0 … 1.0 in / s RMS | 0.0 … 25.4 mm / s RMS | [1]" |
| Output area | 4 … 20 mA | ||
| frequency range (± 10%) | 600 … 60,000 cpm | 10 … 1,000 Hz | [2] [3] |
| Wide band resolution | 0.005 in / s RMS | 0.13 mm / s pk | [4] |
| Linearity error | ≤1% | ||
| conditions of use | |||
| temperature range | -40 … 185 ° F | -40 … 85 ° C | |
| technical Properties | |||
| supply voltage | 12 … 30 V DC | ||
| settling time (on final value ±2%) | < <5 s | ||
| Electrical insulation (housing) | > 100,000,000 Ω | ||
| physical properties | |||
| size - hex | 1.0 in | 25.4 mm | |
| Size - height | 4.2 in | 107 mm | |
| dimensions (without cable) | 4.7 oz | 131 grams | |
| mounting thread | 1/4 "-28 UNF | No metric equivalent | |
| Assembly torque | 3 … 5 ft-lb | 4 … 7 Nm | |
| sensor element | ceramics" | ||
| Geometry of the sensor element | shear principle | ||
| housing material | stainless steel | ||
| Sealing | hermetically sealed welded | ||
| Electrical connection | integrated armoured cable | ||
| cable outlet | top | ||
| connections (red wire ) | Output signal 4 … 20 mA positive | ||
| pin assigNment (blue wire) | output signal 4 … 20mA negative | ||
| cable length | 10 ft | 3.0 m | |
| cable type | polyurethane | [5] | |
| notes | |||
| [1] | Conversion factor 1 in / sec = 0.0254 m/s. | ||
| [2] | at frequencies below 5 Hz, the output signal fluctuates. | ||
| [3] | 1 Hz 60 = cpm ("Cycles Per Minute": revolutions per minute) | ||
| [4] | typically | ||
| [5] | two-core cable with stainless steel reinforcement | ||
| [6] | details: see PCB Declaration of Conformance PS039 and PS053 | ||
| equipment | |||
| 081A40 | mounting bolts with 1/4 "-28 thread" | -1 | |
| ICS-4 | frequency response calibration from 0 Hz to the upper 10% frequency | -1 | |
| (EX) with ATEX approval | |||
| approval for explosionsgef ährdete atmospheres | DIV II, CL I, GRPS A-D, ExnL, AExnA, IIC T4 | ||
| approval for use in potentially explosive atmospheres | EEx ia IIC T4,-40 ° C ≤ Ta ≤ 80 ° C, II 1 G | ||
| Approval for use in potentially explosive atmospheres | EExnL IIC T4,-40 ° C ≤ Ta ≤ 80 ° C, II 3 G | ||
| approval for use in potentially explosive atmospheres | DIV I, CL I, II, III, GRPS A-G, ExIA, AExia, IIC T4 | ||
| (M) metric mounting | |||
| equipment | |||
| M081A61 | metric mounting bolts with M6 thread | -1 | |
| (RV) Raw signal output≥ 100 MΩ/g (±20%) | |||
| electrical connection | integrated armoured cable | ||
| connections (red wire) | output signal 4 … 20 mA positive | ||
| (Black wire) pin assigNment | output signal 4 … 20mA negative | ||
| pin assigNment (white wire) | raw signal positive | ||
| pin assigNment (green wire) | raw signal negative |