PCB-VO(M)622A01
    zoom_out_map

      PCB-VO(M)622A01

    • Industrial ICP® vibration sensor,
    • With vibration velocity output
    • Measuring range 1.27 m/s,
    • Sensitivity 3.9 V/(m/s),
    • Frequency range 3 … 9,000 Hz,
    • Frequency response calibration,
    • 2-pin female connector above
    • basic data
      sensitivity (±10%)≥ 100 MΩ/(in/s)3,937 mV/(m/s)[1]
      range±50 in / s± 1, 27 m/s
      Frequency range (± 10%)240 … 270,000 cpm4 … 4,500 Hz[5] [6]
      frequency range (± 3 dB)180 … 540,000 cpm3 … 9,000 Hz
      resonance frequency1.200 kcpm20,000 Hz[2]
      wide band resolution450 µin/s11.4 µm/s[2]
      Linearity≤1%[3]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      5,000 g pk49,050 m/s² pkOverload limit (shock)
      Temperature range-65 … 250 ° F-54 … 121 ° C
      technical properties
      settling time (on bias voltage ± 1%)≤ 30 seconds
      Power18… 28 V DC
      constant power supply2 … 10 mA
      output impedance< 100 Ω
      Bias voltage8 … 12 V DC
      spectral noise (10 Hz)40 µin/sec /. √ Hz1.12 µm/sec / √ Hz[2]
      spectral noise (100 Hz)7.0 µin/sec / √ Hz0.18 µm/sec / √ Hz[2]
      Spectral noise (1,000 Hz)0.4 µin/sec / √ Hz0.01 µm/sec / √ Hz[2]
      electrical protectionRFI/ESD
      Electrical insulation≥ 100 MΩ
      physical properties
      size - hex7/8 in22 mm
      size ße - height2.06 in52.3 mm
      mass3.3 oz94 grams
      mounting thread1/4 "-28 threaded[]" 4]
      Assembly torque2 … 5 ft-lb2.7 … 6.8 Nm
      sensor elementceramic
      geometry of the sensor elementShear principle
      housing materialstainless steel
      sealinghermetically sealed welded
      Electrical connection2-pin connector (MIL-C-5015)
      connection positionabove
      notes
      [1]Conversion factor 1 g = 9.81 m/s²
      [2]typically
      [3]zero-based balancing line, determined using the method of least squares
      [4]no equivalent in SI units
      [5]the upper cut-off frequency tolerance: ±10%
      [6]1 Hz 60 = cpm ("Cycles Per Minute": rpm).
      [7]details: see PCBs Declaration of conformance PS023 and PS061
      equipment
      081A40mounting bolts with 1/4 "-28 thread-1
      ICS-1frequency response for" Uni-axial sensors from 10 Hz up to the upper 5% frequency-1
      (M) metric mounting
      equipment
      M081A61 Metric mounting bolts with M6 thread-1
      (EX) with ATEX approval
      approval for use in potentially explosive atmospheresEEx ia IIC T4,-54 ° C ≤ Ta ≤ 121 ° C, II 1 G
      (CS) CSA-approved
      approval for use in potentially explosive atmospheresCL I, div I, groups A, B, C, D CL
      II, div I, groups E, F, G Cl
      III, div I
      Approval for use in potentially explosive atmospheresExIA IIC T4, AExia IIC, T4
      approval for use in potentially explosive atmospheresCL I, div 2, Groups A, B, C, D
      ExnL IIC T4, AExnA IIC T4
      PCB-VO(M)622A01

      Specific References

      Download

      VO622A01_drawing.PDF

      Technical drawing

      Download (84.56k)

      VO622A01_manual.PDF

      Operating instructions

      Download (872.66k)

      VO622A01_specs.PDF

      Technical data sheet

      Download (88.53k)