PCB-353B34
- ICP® vibration sensor,
- Measurement range 50 g,
- Sensitivity 100 mV/g,
- Frequency range 1... 4,000 Hz,
- 10-32 female connector above
basic data | |||
Sensitivity (± 5%) | 100 mV / g | 10.19 mV / (m / s) | [1] |
measuring range | ± 50 g pk | ± 491 m / s pk | |
Frequency range (± 5%) | 1 ... 4000 Hz | ||
Frequency range (± 10%) | 0.7 ... 7000 Hz | ||
Frequency range (± 3 dB) | 0.35 ... 12,000 Hz | ||
resonant frequency | ≥22.000 Hz | ||
Broadband resolution | 0.0005 g RMS | 0.005 m / s RMS | [4] |
linearity error | ≤1% | [2] | |
Lateral acceleration sensitivity | ≤5% | [3] | |
Operating conditions | |||
Overload limit (shock) | ± 10,000 g pk | ± 98,100 m / s² pk | |
The temperature range (operation) | -65 ... 250 ° F | -54 ... 121 ° C | |
Strain sensitivity (base surface) | 0.0002 g / µε | 0,002 (m / s²) / µε | [4] |
Technical characteristics | |||
supply voltage | 20 ... 30 V DC | ||
Constant current supply | 2 ... 20 mA | ||
output impedance | ≤100 Ω | ||
Bias voltage | 7.5 ... 11.5 V DC | ||
discharging | 0.5 ... 2.0 s | ||
Settling time (on the bias voltage ± 10%) | <25 s | ||
Spectral Noise (1 Hz) | 320 µg/√Hz | 3,139 (µm/s²)/√Hz | [4] |
Spectral noise (10 Hz) | 70 µg/√Hz | 687 (µm/s²)/√Hz | [4] |
Spectral noise (100 Hz) | 18 µg/√Hz | 177 (µm/s²)/√Hz | [4] |
Spectral noise (1,000 Hz) | 6.4 µg/√Hz | 63 (µm/s²)/√Hz | [4] |
physical properties | |||
Size - Height | 1.26 in | 32.0 mm | |
Size - Hexagon | 0.75 in | 19.1 mm | |
Dimensions | 0.96 oz | 27 grams | [4] |
sensor element | quartz | ||
Geometry of the sensor element | shear principle | ||
housing material | titanium | ||
seal | Hermetically sealed | ||
electrical connection | 10-32 coaxial | ||
port location | Above | ||
mounting thread | 10-32 female thread | ||
Hints | |||
[1] | Sensitivity tolerance for sensors with B or Q-Option: ± 10% | ||
[2] | Zero-based line of best fit, determined by the method of least squares | ||
[3] | Lateral acceleration sensitivity typically ≤ 3% | ||
[4] | typically, | ||
[5] | Details: see PCB Declaration of Conformance PS023 | ||
included supply | |||
080A109 | mounting wax | -1 | |
080A12 | adhesive mounting | -1 | |
081B05 | Mounting bolts (10-32 to 10-32) | -1 | |
ACS-1 | Frequency response, traceable to NIST (10 Hz up to the top 5% point) | -1 | |
M081B05 | Mounting bolts 10-32 on M6 x 0.75 | -1 | |
(Q) Increased discharge time | |||
Frequency range (± 5%) | 0.1 ... 4,000 Hz | ||
Frequency range (± 10%) | 0.07 ... 7000 Hz | ||
discharging | ?10 s | ||
settling | <120 s | ||
included supply | |||
ACS-4 | Low frequency calibration (phase and amplitude) of 0.5 ... 10 Hz | -1 | |
(B) Reduced bias voltage | |||
Bias voltage | 4.5 ... 7.5 V DC | ||
supply voltage | 12 ... 30 V DC | ||
Constant current supply | 1 ... 20 mA | ||
measuring range | 30 g pk | 294 m / s pk | |
(J) ground isolation | |||
Frequency range (± 5%) | 1 ... 4000 Hz | ||
Frequency range (± 10%) | 0.7 ... 6000 Hz | ||
resonant frequency | 18,000 Hz | ||
electrical insulation | ?100 milliohms | ||
Size - Hexagon | 0.75 in | 19.1 mm | |
Size - Height | 1.23 in | 31.2 mm | |
(W) Waterproof cable connection | |||
port location | Above |