PCB-356A26
    zoom_out_map

      PCB-356A26

    • Triaxial ICP® vibration sensor,
    • Measuring range 100 g,
    • Sensitivity 50 mV / g,
    • Frequency range 1 … 5,000 Hz,
    • 4-pin female connector on the side
    • "
      basic data
      sensitivity (±10%)50 mV / g5.1 mV/(m/s²)
      range±100 g pk ±981 m/s 2 pk
      frequency range (±5%)1 … 5,000 Hz
      Frequency range (± 10%)0.7 … 6,500 Hz
      resonance frequency≥ 25,000 Hz
      wide band resolution 0.0002 g RMS0.002 m/s² RMS[3]
      linearity≤ 1%[2]
      Transverse acceleration sensitivity≤ 5%
      conditions of use
      Overload limit (shock)±7. 000 g PK±68. 600 m/s² pk
      Temperature range (operation)-65 … 250 ° F-54 … 121 ° C[4]
      Strain sensitivity (footprint)0.001 g/µε0.01 (m/s²)/µε[3]
      specifications
      power supply24 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤ 100 Ω
      Bias voltage8 … 12 V DC
      Discharging charging time constant0.4 … 1,0 s
      settlingbr(auf Bias-Spannung ±10 %)< 3 s
      Spectral noise (1 Hz)75 µg / √ Hz736 (µm / s ²) / √ Hz[3]
      spectral noise (10 Hz)15 µg / √ Hz147 (µm / s ²) / √ Hz[3]
      spectral noise (100 Hz)4 µg / √ Hz39.2 (µm / s ²) / √ Hz[3]
      spectral noise (1,000 Hz)2 µg / √ Hz19.6 (µm / s ²) / √ Hz[3]
      Spectral noise (10,000 Hz)1 µg / √ Hz9.8 (µm / s ²) / √ Hz[3]
      physical properties
      sensor elementceramic
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealingHermetic
      Size - height0.55 in14.0 mm
      size - length0.80 in20.3 mm
      Size - width0.55 in14.0 mm
      mass0.37 oz10.5 grams[3]
      wiring1/4"-28 4 " PIN
      connection positionside
      mounting thread10-32 female thread
      Installation torque10 … 20 in-lb113 … 225 NCM
      Notes
      [1]the TEDS option increases the bias voltage to 1 v
      [2]zero-based balancing line, determined using the method of least squares
      [3]typically
      [4]the data for temperatures above 121 ° C applies only for transducers with HT option.
      [5]details: see PCBs Declaration of conformance PS023
      equipment
      080A109mounting wax-1
      080A12adhesive mounting-1
      080A90Superglue-1
      081 B 05mounting bolts (10-32 on 10-32)-1
      ACS-1 T Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency-1
      M081B05mounting bolts 10-32 to M6 x 0.75-1
      (HT) high temperature electronics
      frequency range (& plusmn; 5%)6 … 5,000 Hz
      frequency range (± 10%)5 … 5,000 Hz
      wide band resolution0.0004 g RMS0.004 µm / s ² RMS
      Temperature range-65 … 325 ° F-54 … 163 ° C
      Bias voltage7 … 16 V DC
      Discharging charging time constant0.08 … 0<5 s
      spectral noise (1 Hz)130 µg / √ Hz1,275 (µm / s ²) / √ Hz
      spectral noise (10 Hz)30 µg / √ Hz294 (µm / s ²) / √ Hz
      spectral noise (100 Hz)10 µg / √ Hz98.1 (µm / s ²) / √ Hz
      spectral noise (1,000 Hz)3 µg / √ Hz29.4 (µm / s ²) / √ Hz
      Spectral noise (10,000 Hz)2 µg / √ Hz19.6 (µm / s ²) / √ Hz
      (T) TEDS memory in accordance with IEEE PP1451. 4
      Bias voltage8.7 … 13.0 V DC
      (TLA) TEDS LMS International - free Format
      Bias voltage8.7 … 13.0 V DC
      (TLB) TEDS LMS international - format for the automotive industry
      Bias voltage8.7 … 13.0 V DC
      (TLC) TEDS LMS international - format for the aviation industry
      Bias voltage8.7 … 13.0 V DC
      (TLD) TEDS memory in accordance with IEEE P1451. 4
      Bias voltage8.7 … 13.0 V DC
      "
      PCB-356A26

      Specific References

      Download

      356A26_drawing.PDF

      Technical drawing

      Download (41.9k)

      356A26_manual.PDF

      Operating instructions

      Download (1.75M)

      356A26_specs.PDF

      Technical data sheet

      Download (92.32k)