PCB-(M)352A60
basic data | |||
sensitivity (±15%) | 10 mV / g | 1.02 mV/(m/s²) | |
range | ±500 g pk | ±4. 905 m/s 2 pk | [1] |
frequency range (± 3 dB) | 5…60.000 Hz | ||
Electric filter corner frequency | 45,000 Hz | [5] | |
edge steepness of the filter | 10 dB/decade | [5] | |
resonance frequency | ≥ 95,000 Hz | ||
wide band resolution | 0.002 g RMS | 0.02 m/s² RMS | [2] |
linearity | ≤ 1% | [3] | |
transverse acceleration sensitivity | ≤ 5% | [4] | |
Conditions of use | |||
Overload limit (shock) | ±5. 000 g pk | ±49. 050 m/s² pk | |
Temperature range | -65… 250 ° F | -54 … 121 ° C | |
strain sensitivity (base area) | ≤ 0.05 g/µε | ≤ 0.49 (m/s²)/µε | [2] |
Technical characteristics | |||
Supply voltage | 18 … 30 V DC | ||
Constant power supply | 2 … 20 mA | [1] | |
output impedance | ≤ 100 Ω | ||
Bias voltage | 8 … 12 V DC | ||
Discharging charging time constant | 0.02 … 0.06 s | [5] | |
spectral noise (10 Hz) | 160 µg / √ Hz | 1.570 (µm / s ²) /. √ Hz | [2] |
spectral noise (100 Hz) | 40 µg / √ Hz | 390 (µm / s ²) / √ Hz | [2] |
spectral noise (1,000 Hz) | 15 µg / √ Hz | 147 (µm / s ²) / √ Hz | [2] |
spectral noise (10,000 Hz) | 10 µg / √ Hz | 98 (µm / s ²) / √ Hz | [2] |
Physical properties | |||
size-Height | 0.81 in | 21.6 mm | |
size - hex | 3/8 in | 9.5 mm | |
weight | 0.21 oz | 6.0 grams | [2] |
Sensor element | ceramic | ||
geometry of the sensor element | shear principle | ||
housing material | Stainless steel | ||
Sealing | hermetically sealed welded | ||
electrical connection | 5-44 coaxial | ||
Connection position | above | ||
mounting | fixed external thread | ||
mounting thread | 10-32 male | ||
Notes | |||
[1] | for cable lengths over 15 meters, the constant current must be at least 6 mA, so that errors are avoided and the full frequency range can be used. | ||
[2] | typically | ||
[3] | zero-based balancing line, determined using the method of least squares | ||
[4] | transverse acceleration sensitivity typically ≤ 3% | ||
[5] | calculated | ||
[6] | details: see PCBs Declaration of conformance PS023 | ||
Accessories | |||
ACS-52 | frequency response calibration (UNI-axial) over the entire ±3dB range | -1 | |
(M) metric mounting | |||
mounting thread | M6 x 0.75 male | ||
(A) glue mounting | |||
mounting | adhesive Assembly | ||
Mounting thread | does not exist (bonding) | ||
size - hex | 3/8 in | 9.5 mm | |
Gr öße - height | 0.68 | 17.3 | |
equipment | |||
080A90 | cyano | -1 |