PCB-(M)352A60
zoom_out_map

PCB-(M)352A60

  • ICP® vibration sensor,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 5 … 60,000 Hz,
  • 5-44 female connector above
  • basic data
    sensitivity (±15%) 10 mV / g 1.02 mV/(m/s²)
    range ±500 g pk ±4. 905 m/s 2 pk [1]
    frequency range (± 3 dB) 5…60.000 Hz
    Electric filter corner frequency 45,000 Hz [5]
    edge steepness of the filter 10 dB/decade [5]
    resonance frequency ≥ 95,000 Hz
    wide band resolution 0.002 g RMS 0.02 m/s² RMS [2]
    linearity ≤ 1% [3]
    transverse acceleration sensitivity ≤ 5% [4]
    Conditions of use
    Overload limit (shock) ±5. 000 g pk ±49. 050 m/s² pk
    Temperature range -65… 250 ° F -54 … 121 ° C
    strain sensitivity (base area) ≤ 0.05 g/µε ≤ 0.49 (m/s²)/µε [2]
    Technical characteristics
    Supply voltage 18 … 30 V DC
    Constant power supply 2 … 20 mA [1]
    output impedance ≤ 100 Ω
    Bias voltage 8 … 12 V DC
    Discharging charging time constant 0.02 … 0.06 s [5]
    spectral noise (10 Hz) 160 µg / √ Hz 1.570 (µm / s ²) /. √ Hz [2]
    spectral noise (100 Hz) 40 µg / √ Hz 390 (µm / s ²) / √ Hz [2]
    spectral noise (1,000 Hz) 15 µg / √ Hz 147 (µm / s ²) / √ Hz [2]
    spectral noise (10,000 Hz) 10 µg / √ Hz 98 (µm / s ²) / √ Hz [2]
    Physical properties
    size-Height 0.81 in 21.6 mm
    size - hex 3/8 in 9.5 mm
    weight 0.21 oz 6.0 grams [2]
    Sensor element ceramic
    geometry of the sensor element shear principle
    housing material Stainless steel
    Sealing hermetically sealed welded
    electrical connection 5-44 coaxial
    Connection position above
    mounting fixed external thread
    mounting thread 10-32 male
    Notes
    [1] for cable lengths over 15 meters, the constant current must be at least 6 mA, so that errors are avoided and the full frequency range can be used.
    [2] typically
    [3] zero-based balancing line, determined using the method of least squares
    [4] transverse acceleration sensitivity typically ≤ 3%
    [5] calculated
    [6] details: see PCBs Declaration of conformance PS023
    Accessories
    ACS-52 frequency response calibration (UNI-axial) over the entire ±3dB range -1
    (M) metric mounting
    mounting thread M6 x 0.75 male
    (A) glue mounting
    mounting adhesive Assembly
    Mounting thread does not exist (bonding)
    size - hex 3/8 in 9.5 mm
    Gr öße - height 0.68 17.3
    equipment
    080A90 cyano -1
    PCB-(M)352A60

    Specific References

    Download

    352A60_drawing.PDF

    Technical drawing

    Download (33.11k)

    352A60_manual.PDF

    Operating instructions

    Download (1.73M)

    352A60_specs.PDF

    Technical data sheet

    Download (85.16k)