PCB-(M)352A60
    zoom_out_map

      PCB-(M)352A60

    • ICP® vibration sensor,
    • Measuring range 500 g
    • Sensitivity 10 mV / g,
    • Frequency range 5 … 60,000 Hz,
    • 5-44 female connector above
    • basic data
      sensitivity (±15%)10 mV / g1.02 mV/(m/s²)
      range±500 g pk ±4. 905 m/s 2 pk[1]
      frequency range (± 3 dB)5…60.000 Hz
      Electric filter corner frequency45,000 Hz[5]
      edge steepness of the filter10 dB/decade[5]
      resonance frequency≥ 95,000 Hz
      wide band resolution0.002 g RMS0.02 m/s² RMS [2]
      linearity≤ 1%[3]
      transverse acceleration sensitivity≤ 5%[4]
      Conditions of use
      Overload limit (shock)±5. 000 g pk±49. 050 m/s² pk
      Temperature range-65… 250 ° F-54 … 121 ° C
      strain sensitivity (base area)≤ 0.05 g/µε≤ 0.49 (m/s²)/µε[2]
      Technical characteristics
      Supply voltage18 … 30 V DC
      Constant power supply2 … 20 mA[1]
      output impedance≤ 100 Ω
      Bias voltage8 … 12 V DC
      Discharging charging time constant0.02 … 0.06 s[5]
      spectral noise (10 Hz)160 µg / √ Hz1.570 (µm / s ²) /. √ Hz[2]
      spectral noise (100 Hz)40 µg / √ Hz390 (µm / s ²) / √ Hz[2]
      spectral noise (1,000 Hz)15 µg / √ Hz147 (µm / s ²) / √ Hz[2]
      spectral noise (10,000 Hz)10 µg / √ Hz98 (µm / s ²) / √ Hz[2]
      Physical properties
      size-Height0.81 in21.6 mm
      size - hex3/8 in9.5 mm
      weight0.21 oz6.0 grams[2]
      Sensor elementceramic
      geometry of the sensor elementshear principle
      housing materialStainless steel
      Sealinghermetically sealed welded
      electrical connection5-44 coaxial
      Connection positionabove
      mountingfixed external thread
      mounting thread10-32 male
      Notes
      [1]for cable lengths over 15 meters, the constant current must be at least 6 mA, so that errors are avoided and the full frequency range can be used.
      [2]typically
      [3]zero-based balancing line, determined using the method of least squares
      [4]transverse acceleration sensitivity typically ≤ 3%
      [5]calculated
      [6]details: see PCBs Declaration of conformance PS023
      Accessories
      ACS-52frequency response calibration (UNI-axial) over the entire ±3dB range-1
      (M) metric mounting
      mounting threadM6 x 0.75 male
      (A) glue mounting
      mountingadhesive Assembly
      Mounting threaddoes not exist (bonding)
      size - hex3/8 in9.5 mm
      Gr öße - height0.6817.3
      equipment
      080A90cyano-1
      PCB-(M)352A60

      Specific References

      Download

      352A60_drawing.PDF

      Technical drawing

      Download (33.11k)

      352A60_manual.PDF

      Operating instructions

      Download (1.73M)

      352A60_specs.PDF

      Technical data sheet

      Download (85.16k)