PCB-(M)102A05
basic data | |||
measuring range (±5 V output range) | 100 psi | 690 kPa | |
usable range (output range ±10 V) | 1,379 kPa | [2] | |
Sensitivity (± 10 mV/psi) | 50 mV / psi | 7.3 mV / kPa | |
maximum static pressure | 1,000 psi | 6,900 kPa | |
Resolution | 0.002 psi | 0.014 kPa | |
Resonance frequency | ≥250,000 Hz | ||
rise time (reflected pressure) | ≤ 2.0 µs | ||
Lower cut-off frequency (-5%) | 0.5 Hz | ||
Linearity | ≤1.0% FS | [1] | |
conditions | |||
acceleration sensitivity | ≤ 0.002 psi/g | ≤ 0,0014 kPa/(m/s²) | |
Temperature range (operation) | -100 … 275 ° F | -73 … 135 ° C | |
Temperature coefficient of sensitivity | ≤ 0.03 %/°F | ≤ 0,054 %/°C | |
maximum shock (f & uuml; r fraction of a second) | 3,000 ° F | 1,650 ° C | |
maximum shock resistance | 20,000 g pk | 196,000 m/s² PK | |
Technical features | |||
output polarity (positive pressure) | positive | ||
discharging charging time constant (at room temperature) | ≥ 1.0 s | ||
Supply | 20 … 30 V DC | ||
constant power supply | 2 … 20 mA | ||
output impedance | < 100Ω | ||
Bias voltage | 8 … 14 V DC | ||
Electrical insulation | 100 MΩ | ||
physical properties | |||
geometry of the sensor element | compression principle | ||
Sensor element | quartz | ||
housing material | stainless steel | ||
membrane | INVAR | ||
Sealing | hermetically sealed welded | ||
electrical connection | 10-32-coaxial socket | ||
Mass | 0.41 oz | 11.6 grams | |
notes | |||
[1] | zero-based balancing line, determined using the method of least squares | ||
[2] | for output range supply voltage up to 10 V must be at least 24 V DC. At low bias voltage of the sensor, no negative output range is usable up to-10 V. | ||
[3] | details: see PCBs Declaration of conformance PS023 | ||
equipment | |||
065A03 | sealing ring, 0.435 "au need x 0,377 "x 0.030" high brass | 3 | |
(M) metric mounting | |||
equipment | |||
065A40 | Seal ring, 0.435 "outside x 0,397" x 0.030 "high brass | 3 | |
(S) stainless steel diaphragm | |||
diaphragm | 316 L (stainless steel) |