PCB-(M)101A06
zoom_out_map

PCB-(M)101A06

  • ICP® pressure sensor with INVAR-membrane,
  • Masseisoliert,
  • Beschleunigungskompensiert,
  • Measuring range 3.450 kPa,
  • Sensitivity 1.45 mV / kPa,
  • Lower limiting frequency 0.01 Hz,
  • 10-32 female connector
  • of<t? 100 M??

    basic data
    measuring range (±5 V output range) 500 psi 3,450 kPa  
     
    usable range (output range ±10 V) 1,000 psi 7,900 kPa [2]
     
    sensitivity (± 1 mV/psi) 10 mV / psi 1.45 mV / kPa  
     
    maximum static pressure 5,000 psi 34,500 kPa  
     
    Resolution 0.01 psi kPa 0.07  
     
    resonance frequency ≥400,000 Hz    
     
    rise time (reflected pressure) ≤ 1.5 µs    
     
    Lower limiting frequency (-5%) 0.01 Hz    
     
    linearity ≤2.0% FS   [1]
    Conditions of use
    acceleration sensitivity ≤ 0.002 psi/g ≤ 0,0014 kPa/(m/s²)  
     
    temperature range (operation) -100 … 275 ° F -73 … 135 ° C  
     
    Temperature coefficient of sensitivity ≤ 0.03 %/°F ≤ 0,054 %/°C  
     
    maximum shock (ffor fraction of a second) 3,000 ° F 5,400 ° C  
     
    maximum shock resistance 20,000 g pk 196,000 m/s² PK  
    Technical features
    output polarity (positive pressure) positive    
     
    discharging charging time constant (at room temperature) ≥ 50 s    
     
    Supply 20 … 30 V DC    
     
    constant power supply 2 … 20 mA    
     
    output impedance ≤100 Ω    
     
    Bias voltage 8 … 14 V DC    
     
    Electrical insulation    
    physical properties
    geometry of the sensor element compression principle    
     
    Sensor element quartz    
     
    housing material stainless steel    
     
    membrane INVAR    
     
    sealing hermetically sealed welded    
     
    electrical connection 10-32-coaxial socket    
     
    Mass 0.44 oz 12.5 grams  
    notes
    [1] zero-based balancing line, determined using the method of least squares    
     
    [2] for output range supply voltage up to 10 V must be at least 24 V DC. At low bias voltage of the sensor, no negative output range is usable up to-10 V.    
     
    [3] details: see PCBs Declaration of conformance PS023    
    equipment
    065A03 sealing ring, 0.435 "au need x 0,377 "x 0.030" high brass 3  
    (M) metric mounting
    equipment      
     
    065A40 Seal ring, 0.435 "outside x 0,397" x 0.030 "high brass 3  
    (S) stainless steel diaphragm
    diaphragm 316 L (stainless steel)    
    PCB-(M)101A06

    Specific References

    Download

    101A06_drawing.PDF

    Technical drawing

    Download (52.76k)

    101A06_manual.PDF

    Operating instructions

    Download (461.56k)

    101A06_specs.PDF

    Technical data sheet

    Download (158.34k)