PCB-(M)355B33
| basic data | |||
| sensitivity (±10%) | 10.2 mV/(m/s²) | ||
| range | ±50 g pk | ±490 m/s 2 pk | |
| frequency range (±5%) | 2 … 5,000 Hz | ||
| Frequency range (± 10%) | 1 … 10,000 Hz | ||
| frequency range (± 3 dB) | 0,5 … 12,000 Hz | ||
| Resonance frequency | ≥25,000 Hz | ||
| wide band resolution | 0.0005 g RMS | 0.005 m/s² RMS | [1] |
| Linearity | ≤1% | [3] | |
| transverse acceleration sensitivity | ≤5% | [2] | |
| conditions of use | |||
| Overload limit (shock) | ±5. 000 g pk | ±49. 050 m/s² pk | |
| Temperature range (operation) | -65 … 250 ° F | -54 … 121 ° C | |
| specifications | |||
| power supply | 22 … 30 V DC | ||
| constant power supply | 2 … 20 mA | ||
| output impedance | ≤100 Ω | ||
| Bias voltage | 11 … 16 V DC | ||
| discharging charging time constant | 0.5 … 2.0 s | ||
| Settling time < br(auf Bias-Spannung ±10 %) | < 20 s | ||
| spectral noise (1 Hz) | 240 µg / √Hz | 2,350 (µm / s ²) / √Hz | [1] |
| spectral noise (10 Hz) | 65 µg / √Hz | 640 (µm / s ²) / √Hz | [1] |
| spectral noise (100 Hz) | 15 µg /. ? Hz | 150 (µm / s ²) / √Hz | [1] |
| spectral noise (1,000 Hz) | 5 µg / √Hz | 50 (µm / s ²) / √Hz | [1] |
| Electrical insulation (base) | ≥100 MΩ | ||
| physical properties | |||
| size - height | 0.40 in | 10.2 mm | |
| size - length | 0.70 in | 17.8 mm | |
| size - width | 0.63 in | 15.9 mm | |
| mass | 0.39 oz | 11 g | [1] |
| Sensor element | quartz | ||
| geometry of the sensor element | shear principle | ||
| housing material | titanium | ||
| Sealing | hermetically sealed | ||
| electrical connection | 10-32-coaxial socket | ||
| Connecting position | side | ||
| mounting | hole | ||
| notes | |||
| [1] | typically | ||
| [2] | transverse acceleration sensitivity typically ≤ 3% | ||
| [3] | zero-based balancing line, determined using the method of least squares | ||
| [4] | details: see PCBs Declaration of conformance PS023 | ||
| equipment | |||
| 039A22 | Allen wrench, 7/64 "Allen | -1 | |
| 080A109 | mounting wax | -1 | |
| 081 B 45 | insulated mounting screw, 6-32 thread x 5/8 "long (for the model 355 B-02) | -1 | |
| ACS-1 | frequency response, traceable to NIST (10 Hz up to the upper 5% point) | -1 | |
| (M) metric Assembly | |||
| equipment | |||
| M039A22 | Allen wrench for use with thread M3 | -1 | |
| M081B45 | metric mounting screw | -1 | |
| (T) TEDS memory in accordance with IEEE PP1451. 4 | |||
| supply | 24 … 30 V DC | ||
| Bias voltage | 11.7 … 17 V DC |