basic data | |||
sensitivity (±10%) | 5 mV / g | 0.51 mV/(m/s²) | |
range | ± 1.000 g pk | ±9. 810 m/s² pk | |
frequency range (±5%) | 1 … 10,000 Hz | ||
Frequency range (± 10%) | 0.7 … 20,000 Hz | ||
frequency range (± 3 dB) | 0.35 … 30,000 Hz | ||
Resonance frequency | ≥ 70,000 Hz | ||
wide band resolution | 0.01 g RMS | 0.1 m/s² RMS | [1] |
Linearity | ≤ 1% | [2] | |
transverse acceleration sensitivity | ≤ 5% | [3] | |
conditions of use | |||
(Shock) overload limit | ± 10.000 g pk | ±98.100 m/s² pk | |
Temperature range (operation) | -65 … 250 ° F | -54 … 121 ° C | |
Strain sensitivity (base area) | ≤ 0.005 g/µε | ≤ 0.05 (m/s²)/µε | [1] |
technical characteristics | |||
Supply voltage | 18 … 30 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | ≤ 100 Ω | ||
Bias voltage | 8 … 12 V DC | ||
discharging charging time constant | 0.5 … 2.0 s | ||
Settling time < br(auf Bias-Spannung ±10 %) | <5 s | ||
spectral noise (1 Hz) | 6,400 µg / √ Hz | 62.784 (µm / s ²) / √ Hz | [1] |
spectral noise (10 Hz) | 1,400 µg / √ Hz | 13.734 (µm / s ²) / √ Hz | [1] |
spectral noise (100 Hz) | 360 µg / √ Hz | 3.532 (µm / s ²) / √ Hz | [1] |
Spectral noise (1,000 Hz) | 128 µg / √ Hz | 1.256 (µm / s ²) / √ Hz | [1] |
Physical properties | |||
Size - height | 0.68 in | 17.3 mm | |
Size - Allen | 9/32 in | 7.1 mm | |
mass | 0.05 oz | 1.5 grams | [1] |
sensor element | quartz | ||
Geometry of the sensor element | shear principle | ||
housing material | titanium | ||
Sealing | Hermetic | ||
Electrical connection | 5-44 coaxial | ||
connection position | above | ||
Mounting thread | 5-40 male | ||
Assembly torque | 8 … 12 in-lb | 90 … 135 NCM | |
notes | |||
[1] | Typically | ||
[2] | zero-based balancing line, determined using the method of least squares | ||
[3] | Transverse acceleration sensitivitytypically ≤ 3% | ||
[4] | details: see PCBs Declaration of conformance PS023 | ||
equipment | |||
080A109 | Mount wax | -1 | |
080A15 | adhesive mounting | -1 | |
ACS-1 | frequency response, r ückführbar on NIST (10 Hz up to the upper 5% point) | -1 | |
(M) metric mounting | |||
mounting thread | M3 x 0.50 male | ||
Accessories | |||
M080A15 | adhesive mounting | -1 | |
(A) glue Assembly | |||
Accessories | |||
080A90 | cyano | -1 | |
(B) reduced bias voltage | |||
Bias voltage | 4.5 … 7.5 V DC | ||
Power | 12 … 30 V DC | ||
Constant power supply | 1 … 20 mA | ||
Measuring range | 600 g pk | 5.886 m/s² pk | |
(J) mass insulation | |||
Frequency range (±5%) | 1 … 8,000 Hz | ||
frequency range (± 10%) | 0.7 … 15,000 Hz | ||
Resonance frequency | 56,000 Hz | ||
electrical insulation | ≥100 MΩ | ||
size - hex | 3/8 in | 9.5 mm | |
Size - height | 0.76 in | 19.3 mm | |
mass | 0.09 oz | 2.7 grams | |
(Q) increased Discharge charge time constant | |||
frequency range (±5%) | 0.15 … 10,000 Hz | ||
frequency range (± 10%) | 0.1 … 20,000 Hz | ||
Discharging charging time constant | ><5 s | ||
settling time | < 45s | ||
includedAccessories | |||
ACS-97 | low frequency calibration of 1 … 10 Hz | -1 | |
(W) waterproof cable | |||
Connecting position | top |