PCB-(M)350B21
zoom_out_map

PCB-(M)350B21

  • ICP® shock acceleration sensor,
  • Masseisoliert,
  • Measuring range 100,000 g,
  • Sensitivity 0.05 mV / g,
  • Frequency range 1 … 10,000 Hz,
  • Integrated connection cable, length 3 m,
    ending on 10-32 plug,
  • no longer available (replacement: ) PCB-(M)350B01)
  •  

    basic data
    sensitivity (±30%) /0.05 mV / g 0.005 mV/(m/s²)  
     
    range ±100. 000 g PK ±980. 000 m/s² pk  
     
    Frequency range (± 1 dB) 1 … 10,000 Hz    
     
    frequency range (± 3 dB) 0,5 … 35,000 Hz    
     
    Resonance frequency ≥ 200.000 Hz    
     
    wide band resolution 0.3 g RMS 2,9 m/s² RMS [1]
     
    Linearity error (per 10,000 g / 98.100 m/s²) ±0. 5%   [2]
     
    transverse acceleration sensitivity ≤ 7%    
    Conditions of use
    Overload limit (shock) ±200. 000 g pk ±1. 960.000 m/s² pk  
     
    Temperature range (operation) -65 …200 °F -54 … 93 ° C  
     
    Strain sensitivity (footprint) 0.2 g/µε 2.0 (m/s²)/µε [1]
    technical characteristics
    Supply voltage 18 … 30 V DC    
     
    constant power supply 2 … 20 mA    
     
    Output impedance ≤100 Ω    
     
    Bias voltage 8 … 12 V DC    
     
    discharging charging time constant 0.5 … 0,7 s   [1]
     
    Settling time < br(auf Bias-Spannung ±10 %) <5 s    
     
    electrical insulation (housing)  >100 MΩ  
    Physical properties
    Sensor element ceramic    
     
    Geometry of the sensor element shear principle    
     
    housing material titanium    
     
    sealing Hermetically sealed    
     
    size-Hexagonal 0.375 in 9.5 mm  
     
    size - height 0.73 in 18.5 mm  
     
    dimensions (without cable) 0.15 oz 4.4 grams [1]
     
    Electrical connection integrated cable    
     
    cable length 10 ft 3 m  
     
    cable type type 031,. twisted pair    
     
    mounting thread 1/4 "-28 thread    
    notes
    [1] typically   "
     
    [2] maximum sensitivity drift    
    Accessories
    ACS-14 Hopkinson bar calibration for shock resistance thermometer -1  
     
    ACS-22 frequency response, traceable to NIST (100 Hz to ±1dB point) -1  
    (M) metric mounting
    mounting thread M6 x 0.75 m ännlich    
    PCB-(M)350B21

    Specific References

    Download

    350B21_drawing.PDF

    Technical drawing

    Download (45.44k)

    350B21_manual.PDF

    Operating instructions

    Download (2.02M)

    350B21_specs.PDF

    Technical data sheet

    Download (425.86k)