PCB-(M)350C03
zoom_out_map

PCB-(M)350C03

  • ICP® shock acceleration sensor,
  • With electric and mechanical filter,
  • Measuring range 10,000 g,
  • Sensitivity 0.5 mV / g,
  • Frequency range 0.4 … 10,000 Hz,
  • 10-32 female connector above
  •  

    basic data
    sensitivity (±30%) 0.5 mV / g 0.05 mV/(m/s²)  
     
    range ±10. 000 g pk ±98. 000 m / pk  
     
    Frequency range (± 1 dB) 0.4 … 10,000 Hz    
     
    frequency range (-3 dB) 0.2 … 25,000 Hz   [4]
     
    Corner frequency of the electrical filter (-3 dB) 21,000 Hz   [2] [1]
     
    resonance frequency of the mechanical filter 35,000 Hz   [3] [1]
     
    Resonance frequency ≥ 100,000 Hz    
     
    wide band resolution (1 … 10,000 Hz) 0.39 m/s² rms rms 0.04 g [1]
     
    Linearity error ? ±2. 0%    
     
    transverse acceleration sensitivity ≤ 7%    
    conditions
    Ü berlastlimit (shock) ±50. 000 g pk ±490. 000 m / pk  
     
    temperature range (operation) 0 … 150 ° F -18 … 66 ° C  
     
    temperature range (Storage) -40 …200 °F -40 … 93 ° C  
     
    Strain sensitivity (footprint) 0,002 g/µε 0.02 (m/s²)/µε [1]
    technical characteristics
    Supply voltage 20 … 30 V DC    
     
    constant power supply 2 … 20 mA    
     
    Output impedance ≤200Ω    
     
    Bias voltage 8 … 14 V DC    
     
    discharging charging time constant 1.0 … 2.0 s    
     
    Settling time < br(auf Bias-Spannung ±10 %) < 10 s    
    physical properties
    sensor element ceramic    
     
    Geometry of the sensor element shear principle    
     
    housing material titanium    
     
    sealed sealed close    
     
    size - hex 0.375 in 9.5 mm  
     
    Size - height 1.15 in 29.2 mm  
     
    mass 0.19 oz 5.4 grams [1]
     
    electrical connection 10-32-coaxial socket    
     
    Connection position above    
     
    fixing mounting bolt    
     
    mounting thread 1/4 "-28 thread    
     
    Assembly torque 25 … 35 in-lb 280 … 390 NCM  
    notes
    [1] typically    
     
    [2] second-order low-pass filter    
     
    [3] the amplitude is increased in the resonance frequency by 9 dB.    
     
    [4] the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.    
     
    [5] details: see PCBs Declaration of conformance PS023    
    (M) metric mounting
    mounting thread M6 x 0.75 male    
    (W) waterproof cable connection
    Electrical connection Integrated cord with waterproof connection    
    PCB-(M)350C03

    Specific References

    Download

    350C03_drawing.PDF

    Technical drawing

    Download (92.57k)

    350C03_manual.PDF

    Operating instructions

    Download (1.73M)

    350C03_specs.PDF

    Technical data sheet

    Download (82.7k)