PCB-357A100
- Vibration sensor with charge output, li >
- Continuous use temperature up to 482 ° C,
- With UHT-12™ sensor element,
(no popcorn noise), li > - Measuring range 200 g, li >
- Sensitivity 5 pC/g, li >
- Upper cutoff frequency 5,000 Hz, li >
- 2-pin female connector on the side
| Specifications | |||
|---|---|---|---|
| Basic data | English units | SI units | |
| Sensitivity (≤5 %) | 5.0 pC/g | 0,510 pC/(m/s²) | |
| Measuring range | ±200 g pk | ±1.962 m/s² pk | |
| Frequency range (+ 10%) | 5.000 Hz | [3] | |
| Resonance frequency | 20,000 Hz | [1] | |
| Linearity error | ≤1 % | [4] | |
| Transverse acceleration sensitivity | ≤5 % | [2] | |
| Conditions of use | |||
| Overload limit (shock) | ±1.000 g pk | ±9.810 m/s² pk | |
| Temperature range | -65... 900 ° F | -54... 482 ° C | |
| Technical characteristics | |||
| capacity (from pin to pin) | 120 pF | [1] | |
| capacity (by pin housing) | ≤2 pF | [1] | |
| capacity (Asymmetry between the pins) | ≤2 pF | ||
| ISOlationswiderstand (von Pin auf Gehäuse bei 21 °C) | > 1,000 MΩ | [1] | |
| ISO Lationswiderstand (von Pin auf Pin bei 21 °C) | > 1,000 MΩ | ||
| ISO Lationswiderstand ( from pin to pin at 482 ° C) | > 100 k Ω | ||
| physical properties | |||
| sensor element | UHT-12™ | ||
| geometry of the sensor element | shear principle | ||
| Housing material | Inconel | ||
| sealing | hermetically sealed | ||
| size - height | 0.75 in | 19 mm | |
| size -. Diameter | 1.5 in | 38.1 mm | |
| size - length | 1.88 in | 47.8 mm | |
| mass | 2.32 oz | 65.8 g | [1] |
| electrical connection | 7/16-27 2-pin | ||
| Connection position | side | ||
| mounting | 3 holes | ||
| notes | |||
|---|---|---|---|
| [1] | typeischerweise | ||
| [2] | Transverse acceleration sensitivity typically ≤3% | ||
| [3] | The lower cut-off frequency depends on the used signal conditioning electronics. | ||
| [4] | Zero-balance just, determined using the method of least squares | ||
| Included accessories | ||
|---|---|---|
| 081A99 | Mounting screws | (3) |
| ICS-8 | Frequency response calibration of 600 cpm (10 Hz) up to the upper 10% frequency. | (1) |