PCB-356A03
    zoom_out_map

      PCB-356A03

    • Triaxial ICP® miniature vibration sensor,
    • Mass 1 gram,
    • Measuring range 500 g
    • Sensitivity 10 mV / g,
    • Frequency range 2 … 8,000 Hz,
    • Integrated connection cable, length 1.5 m,
      ending on 4-pin female connector,
    • including extension cable, length 1.5 m,
      ending to three BNC
    • basic data
      sensitivity (±20%)10 mV / g1.02 mV/(m/s²)
      range±500 g pk ±4. 905 m/s 2 pk
      frequency (Y - and Z-axis) < br(≤5 %)2 … 8,000 Hz
      Frequency range (X-axis) (±5%)2 … 5,000 Hz
      frequency range (X-axis) (+ 1 dB)≥ 8,000 Hz
      Resonance frequency≥ 50,000 Hz
      Wide band resolution0.003 g RMS0.03 m/s² RMS[2]
      Linearity error≤ 1%[1]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      Overload limit (shock)±5. 000 g PK±49. 050 m/s² pk
      Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
      specifications
      power supply21 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤ 100 Ω
      Bias voltage9 … 15 V DC
      Discharging charging time constant0.24 … 1,0 s
      settlingbr(auf Bias-Spannung ±10 %)< 3 s
      Spectral noise (1 Hz)1.200 ?g / √ Hz11.772 (µm / s ²) / √ Hz[2]
      spectral noise (10 Hz)300 µg / √ Hz2.943 (µm / s ²) / √ Hz[2]
      spectral noise (100 Hz)100 µg / √ Hz981 (µm / s ²) / √ Hz[2]
      spectral noise ( 1,000 Hz)30 µg / √ Hz294 (µm / s ²) / √ Hz[2]
      physical properties
      sensor elementceramic
      Geometrythe sensor elementshear principle
      housing materialtitanium
      sealinghermetic
      Size - height0.25 in6.35 mm
      size - length0.25 in6.35 mm
      Gr size - width0.25 in6.35 mm
      dimensions (without cable)0.04 oz1.0 grams[2]
      wiringintegrated cable
      Cable exitside
      cable termination1/4 "-28 4-pin socket
      " Cable length5 ft1.5 m
      cord typetype 034, 4-wire shielded cable
      attachmentbonding
      Notes
      [1]zero-based balancing line, determined using the method of least squares
      [2]typically
      [3]Details: See PCBs Declaration of conformance PS023
      Accessories
      034 G 054-wire shielded cables, 1.5 meter, 4-pin connector to three BNC-1
      080A109mounting wax-1
      080A90cyano-1
      ACS-1 Tfrequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the top 5% -. Frequency-1
      PCB-356A03

      Specific References

      Download

      356A03_drawing.PDF

      Technical drawing

      Download (556.65k)

      356A03_specs.PDF

      Technical data sheet

      Download (83.19k)

      356A03_manual.PDF

      Operating instructions

      Download (2.13M)