PCB-356A03
basic data | |||
sensitivity (±20%) | 10 mV / g | 1.02 mV/(m/s²) | |
range | ±500 g pk | ±4. 905 m/s 2 pk | |
frequency (Y - and Z-axis) < br(≤5 %) | 2 … 8,000 Hz | ||
Frequency range (X-axis) (±5%) | 2 … 5,000 Hz | ||
frequency range (X-axis) (+ 1 dB) | ≥ 8,000 Hz | ||
Resonance frequency | ≥ 50,000 Hz | ||
Wide band resolution | 0.003 g RMS | 0.03 m/s² RMS | [2] |
Linearity error | ≤ 1% | [1] | |
transverse acceleration sensitivity | ≤ 5% | ||
conditions of use | |||
Overload limit (shock) | ±5. 000 g PK | ±49. 050 m/s² pk | |
Temperature range (operation) | -65 … 250 ° F | -54 … 121 ° C | |
specifications | |||
power supply | 21 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | ≤ 100 Ω | ||
Bias voltage | 9 … 15 V DC | ||
Discharging charging time constant | 0.24 … 1,0 s | ||
settlingbr(auf Bias-Spannung ±10 %) | < 3 s | ||
Spectral noise (1 Hz) | 1.200 ?g / √ Hz | 11.772 (µm / s ²) / √ Hz | [2] |
spectral noise (10 Hz) | 300 µg / √ Hz | 2.943 (µm / s ²) / √ Hz | [2] |
spectral noise (100 Hz) | 100 µg / √ Hz | 981 (µm / s ²) / √ Hz | [2] |
spectral noise ( 1,000 Hz) | 30 µg / √ Hz | 294 (µm / s ²) / √ Hz | [2] |
physical properties | |||
sensor element | ceramic | ||
Geometrythe sensor element | shear principle | ||
housing material | titanium | ||
sealing | hermetic | ||
Size - height | 0.25 in | 6.35 mm | |
size - length | 0.25 in | 6.35 mm | |
Gr size - width | 0.25 in | 6.35 mm | |
dimensions (without cable) | 0.04 oz | 1.0 grams | [2] |
wiring | integrated cable | ||
Cable exit | side | ||
cable termination | 1/4 "-28 4-pin socket | ||
" Cable length | 5 ft | 1.5 m | |
cord type | type 034, 4-wire shielded cable | ||
attachment | bonding | ||
Notes | |||
[1] | zero-based balancing line, determined using the method of least squares | ||
[2] | typically | ||
[3] | Details: See PCBs Declaration of conformance PS023 | ||
Accessories | |||
034 G 05 | 4-wire shielded cables, 1.5 meter, 4-pin connector to three BNC | -1 | |
080A109 | mounting wax | -1 | |
080A90 | cyano | -1 | |
ACS-1 T | frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the top 5% -. Frequency | -1 |