PCB-356B41/NC
    zoom_out_map

      PCB-356B41/NC

      • Triaxial vibration sensor seat cushion,
      • For measurements according to DIN EN 30.326,
      • Measuring range 10 g,
      • Sensitivity 100 mV/g,
      • Frequency range 0.5... 1,000 Hz,
      • Integrated cable, length 1.5 m,
        ending on 4-pin female connector.
      • Without extension cable

       

      basic data
      sensitivity (±10%)100 mV/g10.2 mV/(m/s²) 
       
      measuring range±10 g pk±98 m/s 2 pk 
       
      Frequency range (±5%)0.5... 1,000 Hz [1]
       
      resonance frequency≥27. 000 Hz  
       
      wide band resolution0.0002 g RMS0,002 m/s² RMS[3]
       
      linearity≤1% [2]
       
      transverse acceleration sensitivity≤5%  
      conditions of use
      Overload limit (shock)±2. 000 g pk±19. 620 m/s² pk 
       
      temperature14... 122 ° F10... 50 ° C 
       
      temperature effect≤ 0.10 %/°F< 0.17 %/°C[3]
      specifications
      power supply6.5... 30 V DC  
       
      constant power supply0.3... 10 mA  
       
      output impedance≤500 Ω  
       
      Bias voltage2.8... 4,5 V DC  
       
      discharging charging time constant1... 3 s  
       
      settling time
      (auf Bias-Spannung ±10 %)
      >20 s  
       
      spectral noise (1 Hz)50 µg/√Hz490 (µm/s²)/√Hz[] 3]
       
      spectral noise (10 Hz)10 µg/√Hz98 (µm/s²)/√Hz[3]
       
      spectral noise (100 Hz)4 µg/√Hz39 (µm/s²)/√Hz[3]
       
      Spectral noise (1,000 Hz)2 µg/√Hz20 (µm/s²)/√Hz[3]
      physical properties
      sensor elementceramic  
       
      Geometry of the sensor elementShear principle  
       
      Housing materialTitanium  
       
      SealingHermetic  
       
      Size - diameter7.87 in 
       
      Size - width0.472 in12 mm 
       
      Mass9.6 oz272 grams[3]
       
      Electrical connectionIntegrated cable  
       
      Cable outletOn the side  
       
      Cable termination1/4 "-28 4-pin connector  
       
      Cable length5 ft1.5 m 
       
      Cable typeType 010, 4-conductor shielded cable  
       
      Mounting thread5-40 female  
      Notes
      [1]Standard calibration to 100 Hz with a sensor in the seat cushion. Special calibration about 100 Hz with sensor built in optional.  
       
      [2]Zero-balance just, determined using the method of least squares  
       
      [3]Typically  
       
      [4]Details: see PCBs Declaration of conformance PS023  
      Included accessories
      081A90Mounting bolts, 10-32 on 5-40-1 
       
      ACS-17Calibration of amplitude and phase response, traceable to NIST by 0.5... 100 Hz-1 
      PCB-356B41/NC

      Specific References

      Download

      356B41_NC_manual.PDF

      Operating instructions

      Download (1.96M)

      356B41_drawing.PDF

      Technical drawing

      Download (312.5k)

      356B41_specs.PDF

      Technical data sheet

      Download (30.79k)