PCB-356A72
| basic data | |||
| sensitivity (±20%) | 2.6 pC/g | 0.26 pC/(m/s²) | |
| range | ±500 g pk | ±4. 905 m/s 2 pk | |
| frequency range (+ 5%) | 7,000 Hz | [3] | |
| Frequency range (+ 1 dB) | 8,000 Hz | [3] | |
| resonance frequency | ≥ 20,000 Hz | ||
| linearity | ≤ 1% | ||
| Transverse acceleration sensitivity | ≤ 5% | ||
| conditions of use | |||
| Overload limit (shock) | ±5. 000 g PK | ±49. 050 m/s² pk | |
| Temperature range | -100 … 350 ° F | -73 … 177 ° C | |
| strain sensitivity (footprint) | 0.005 g/µε | 0.05 (m/s²)/µε | [1] |
| Technical properties | |||
| capacity | 240 pF | [1] | |
| Insulation resistance (at 70 ° F [21 ° C]) | ≥ 10,000 M Ω | ||
| electrical insulation (base) | ≥100 MΩ | ||
| Output polarity | negative | [2] | |
| physical properties | |||
| sensor element | ceramic | ||
| geometry of the Sensor element | shear principle | ||
| housing material | anodized aluminum | ||
| sealing | hermetic | ||
| Size - length | 0.80 in | 20.3 mm | |
| size - width | 0.80 in | 20.3 mm | |
| Size - height | 0.46 in | 11.7 mm | |
| mass | 0.50 oz | 14.3 grams | [1] |
| wiring | 10-32-coaxial socket | ||
| Mounting | hole | ||
| notes | |||
| [1] | typically | ||
| [2] | Reference direction: bythe tree in the direction of the sensor | ||
| [3] | the lower cut-off frequency depends on the used signal conditioning electronics. | ||
| Equipment | |||
| 080A109 | mounting wax | -1 | |
| 081A98 | 4-40 screw x. 0.675 "long | 2 | |
| ACS-1 T | frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency | -1 | "|
| M081A98 | metric mounting screw | -2 | |
| (P) positive output voltage | |||
| output polarity | positive |