PCB-356A24
| basic data | |||
| sensitivity (±15%) | 10 mV / g | 1.02 mV/(m/s²) | |
| range | ±500 g pk | ±4. 905 m/s 2 pk | |
| frequency range (±5%) | 1 … 9,000 Hz | ||
| Frequency range (± 10%) | 0.5 … 12,000 Hz | ||
| resonance frequency | ≥ 45,000 Hz | ||
| wide band resolution | 0,004 g RMS | 0.04 m/s² RMS | [1] |
| Linearity | ≤ 1% | [3] | |
| transverse acceleration sensitivity | ≤ 5% | ||
| conditions of use | |||
| (Shock) overload limit | ± 10.000 g pk | ±98.100 m/s² pk | |
| Temperature range (operation) | -65 … 250 ° F | -54 … 121 ° C | [2] |
| Technical properties | |||
| Supply voltage | 18 … 30 V DC | ||
| Constant power supply | 2 … 20 mA | ||
| output impedance | ≤200Ω | ||
| Bias voltage | 7 … 11 V DC | ||
| discharging charging time constant | 1.0 … 3<5 s | ||
| settling time (on Bias-Spannung ±10%) | < 10 s | ||
| spectral noise (1 Hz) | 900 µg / √ Hz | 8.820 (µm / s ²) / √ Hz | [1] |
| Spectral noise (10 Hz) | 250 µg / √ Hz | 2,450 (µm / s ²) / √ Hz | [1] |
| spectral noise (100 Hz) | 100 µg / √ Hz | 981 (µm / s ²) / √ Hz | [1] |
| spectral noise (1,000 Hz) | 50 µg / √ Hz | 490 (µm / s ²) / √ Hz | [1] |
| physical properties | |||
| sensor element | Ceramic | ||
| Geometry of the sensor element | shear principle | ||
| housing material | titanium | ||
| Sealing | sealedclose | ||
| size - height | 0.28 in | 7.0 mm | |
| size - length | 0.47 in | 12.0 mm | |
| Size - width | 0.47 in | 12.0 mm | |
| dimensions (without cable) | 0.11 oz | 3.1 g | [1] |
| electrical connection | 8-36 4-Pin | ||
| connection position | side | ||
| attachment | bonding | ||
| notes | |||
| [1] | typically | ||
| [2] | the data for temperatures above 121 ° C applies only for transducers with HT option. | ||
| [3] | zero-based balancing line, determined using the method of least squares | ||
| [4] | details: see PCBs Declaration of conformance PS023 | ||
| equipment | |||
| 034 K 10 | connection cable, length 3 m, Mini 4-pin connector to three BNC | -1 | |
| 080A109 | Mount wax | -1 | |
| 080A90 | glue | -1 | |
| ACS-1 T | Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency | -1 | |
| (HT) high temperature electronics | |||
| temperature range | -65 … 325 ° F | -54 … 163 ° C | |
| (J) mass insulation of | |||
| electrical insulation | 100,000,000 Ω | ||
| size - height | 0.33 in | x 8.3 mm | |
| size - length | 0.47 in | 12.0 mm | |
| size - width | 0.47 in | 12.0 mm | |
| Weight | 0.13 oz | 3.7 grams |