PCB-350B44
zoom_out_map

PCB-350B44

  • Triaxial ICP® shock acceleration sensor
  • Ground Isolated
  • With electrical and mechanical filter
    (-3 dB at 21,000 Hz)
  • Measuring range 5,000 g
  • Sensitivity 1.0 mV / g
  • Frequency range 0.4 ... 10,000 Hz
  • Integrated connection cable, length 1.5 meters,
    ending on 4-pin connection socket
  • Including extension cable, length 1.5 meters,
    ending on three BNC plugs
specifications
basic dataEnglish unitsSI units 
Sensitivity (± 30%) 1,0 mV/g 0,1 mV/(m/s²)
measuring range ± 5,000 g pk ±49.000 m/s²pk
Frequency range (± 1 dB) 0,4 … 10.000 Hz
Frequency range (-3 dB) 0,2 … 25.000 Hz [2]
resonant frequency ≥50.000 Hz
Corner frequency of the electrical filter
(-3 dB)
21.000 Hz [3][1]
Mechanical filter resonance frequency 35.000 Hz [4][1]
Broadband resolution (1 ... 10,000 Hz) 0,04 gRMS 0,39 m/s²RMS [1]
Linearitätsfehler ≤2 %
Lateral acceleration sensitivity ≤7 %
Operating conditions
Overload limit (shock) ± 50,000 g pk ±490.000 m/s²pk
Temperature range (operation) -10 … 150 °F -23 … 66 °C
Temperature range (storage) -40 … 200 °F -40 … 93 °C
Strain sensitivity (base area) 0.002 g / me 0.02 (m / s²) / me [1]
Technical characteristics
supply voltage 20 … 30 VDC
Constant current supply 2 ... 20 mA
output impedance Ω200 Ω
Bias voltage 8 … 14 VDC
discharging 1,0 … 2,0 s [1]
Settling time
(on bias voltage ± 10%)
<10 s
Electrical insulation (base) >100 MΩ
Physical properties
sensor element ceramics
Geometry of the sensor element Scherprinzip
housing material Titan
seal Hermetically sealed
Size - height 1,02 in 26,0 mm
Size - length 1,02 in 26,0 mm
Size - width 1,02 in 26,0 mm
Mass (without cable) 2,2 oz 62.5 grams [1]
Electrical connection Integrated cable
Kabelabgang Laterally
cable termination 4-pin socket (1/4 "-28)
cable length 5,0 ft 1,52 m
cable type Type 034, shielded 4-wire cable
attachment Through holes

16752_1.gifCEMark.gif[5]

Hints
[1] typically,
[2] The specified upper limit frequency is a guide value. The frequency response is limited by the combination of electrical and mechanical low-pass filters.
[3] Second order low pass filter
[4] The amplitude is increased by 9 dB in the range of the resonance frequency.
[5] Details: siehe PCB Declaration of Conformance PS023

included supply
034G05 Shielded 4-wire cable, length 1.5 meters, 4-pin connector to three BNC connectors (1)
100-16040-40 Mounting screw M6 x 1.0 (2)
100-6774-10 Mounting screw 1/4 "-28 (2)
100-8994-40 grease (1)
ACS-14T Hopkinson bar calibration for shock transducers (1)
ACS-22T Frequency response for triaxial transducers, traceable to NIST (100 Hz up to the upper ± 1dB point (1)
PCB-350B44

Specific References

Download

350B44_specs

350B44_specs

Download (93.21k)

350B44_specs

350B44_specs

Download (125.73k)