PCB-350B43
    zoom_out_map

      PCB-350B43

      • Triaxial ICP® shock acceleration sensor
      • Ground Isolated
      • With electrical and mechanical filter
        (-3 dB at 21,000 Hz)
      • Measuring range 10,000 g
      • Sensitivity 0.5 mV / g
      • Frequency range 0.4 ... 10,000 Hz
      • Integrated connection cable, length 1.5 meters,
        ending on 4-pin connection socket
      • Including extension cable, length 1.5 meters,
        ending on three BNC plugs
      specifications
      basic dataEnglish unitsSI units 
      Sensitivity (± 30%)0,5 mV/g0,05 mV/(m/s²)
      measuring range± 10,000 g pk±98.000 m/s²pk
      Frequency range (± 1 dB)0,4 … 10.000 Hz
      Frequency range (-3 dB)0,2 … 25.000 Hz[2]
      resonant frequency35.000 Hz[1][4]
      Corner frequency of the electrical filter
      (-3 dB)
      21.000 Hz[3][1]
      Broadband resolution (1 ... 10,000 Hz)0,04 gRMS0,39 m/s²RMS[1]
      Non-Linearity≤2 %
      Lateral acceleration sensitivity≤7 %
      Operating conditions
      Overload limit (shock)± 50,000 g pk±490.000 m/s²pk
      Temperature range (operation)-10 … 150 °F-23 … 66 °C
      Temperature range (storage)-40 … 200 °F-40 … 93 °C
      Strain sensitivity (base area)0.002 g / me0.02 (m / s²) / me[1]
      Technical characteristics
      supply voltage20 … 30 VDC
      Constant current supply2 ... 20 mA
      output impedanceΩ200 Ω
      Bias voltage8 … 14 VDC
      discharging1,0 … 2,0 s[1]
      Settling time
      (on bias voltage ± 10%)
      <10 s
      Electrical insulation (base)>100 MΩ
      Physical properties
      sensor elementceramics
      Geometry of the sensor elementShear
      housing materialTitan
      sealHermetically sealed
      Size - height1,02 in26,0 mm
      Size - length1,02 in26,0 mm
      Size - width1,02 in26,0 mm
      Mass (without cable)2,2 oz62.5 grams[1]
      Electrical connectionIntegrated cable
      KabelabgangLaterally
      cable termination4-pin socket (1/4 "-28)
      cable length5,0 ft1,52 m
      cable typeType 034, shielded 4-wire cable
      attachmentThrough holes

      [5]

      Hints
      [1]typically,
      [2]The specified upper limit frequency is a guide value. The frequency response is limited by the combination of electrical and mechanical low-pass filters.
      [3]Second order low pass filter
      [4]The amplitude is increased by 9 dB in the range of the resonance frequency.
      [5]Details: siehe PCB Declaration of Conformance PS023

      included supply
      034G05Shielded 4-wire cable, length 1.5 meters, 4-pin connector to three BNC connectors(1)
      100-16040-40Mounting screw M6 x 1.0(2)
      100-6774-10Mounting screw 1/4 "-28(2)
      100-8994-40grease(1)
      ACS-14THopkinson bar calibration for shock transducers(1)
      ACS-22TFrequency response for triaxial transducers, traceable to NIST (100 Hz up to the upper ± 1dB point(1)