    • Triaxial ICP® shock acceleration sensor,
    • Masseisoliert,
    • With electric filters < br(-3 dB bei?20.000 Hz),
    • range 10,000 g,
    • sensitivity 0.5 mV / g,
    • frequency range 3 … 10,000 Hz,
    • integrated cable, length 1.5 m,
      ending on 4-pin female connector,
    • Including extension cable, length 1.5 m,
      ending to three BNC
    • basic data
      sensitivity (±30%)0.5 mV / g0.05 mV/(m/s²)
      range±10. 000 g PK±98. 000 m/s² pk
      Frequency range (± 1 dB)3 … 10,000 Hz
      frequency range (-3 dB)1.5 … 20,000 Hz[3]
      Resonance frequency≥60.000 Hz
      wide band resolution0.03 g RMS0.29 m/s² RMS[1]
      Linearity≤ 2%[2]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      Overload limit (shock)±25. 000 g pk±245. 000 m/s² pk
      Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
      Technical properties
      Supply voltage18 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤ 100 Ω
      Bias voltage 8 … 12 V DC
      discharging charging time constant0.5 … 1.0 s
      settling time
      (on Bias-Spannung ±10%)
      <5 s
      electrical insulation (base)≥ 100 MΩ
      physical properties
      Sensor elementceramic
      geometry of the sensor elementshear principle
      housing materialtitanium
      Sealinghermetically sealed
      size - height0.32 in8.2 mm
      size -Length0.72 at18.3 mm
      size-Width0.72 at18.3 mm
      dimensions (without cable)0.3 oz8.0 grams[1]
      electrical connectionintegrated cable
      Cable exitside
      cable termination4-pin connector (1/4 "28")
      cable length5.0 ft1.52 m
      cord typetype 034, 4-wire shielded cable
      mountinghole
      Notes
      [1]typically
      [2]zero-based balancing line, determined using the method of least squares
      [3]second-order low-pass filter
      [4]details: see PCBs Declaration of conformance PS023
      Accessories
      034 G 05shielded 4 Conductor cable, length 1.5 m, 4-pin connector to three BNC-1
      080A197mounting plate for the model 350 B 50-1
      081A112insulated mounting screw 6-32 thread x 12.7 mm long (for model 350 B 50)4
      ACS-14 T Hopkinson bar calibration for shock resistance-1
      ACS-22 Tfrequency response for Triaxial accelerometer, traceable to NIST (100 Hz to the upper ±1dB point-1)
      PCB-350B50

      Specific References

      Download

      350B50_drawing.PDF

      Technical drawing

      Download (484.93k)

      350B50_specs.PDF

      Technical data sheet

      Download (452.26k)

      350B50_manual.PDF

      Operating instructions

      Download (2.47M)