PCB-RHM240M40
- Industrial ICP® strain sensor,
- Measuring range 300 µ ?
- Sensitivity 10 mV / µ ?
- Lower limiting frequency 0.004 Hz,
- Integrated cable, length 3 m, ending on cut end
| basic data | |||
| Sensitivity (± 20%) | 10 mV / ?? | ||
| measuring range | 300 ?? pk | [1] | |
| Frequency range (-5%) | 0.004 Hz | [3] | |
| Broadband resolution (1 ... 10,000 Hz) | ?? 0.001 | [2] | |
| linearity error | ?2% | [4] | |
| Operating conditions | |||
| The temperature range (operation) | -65 ... 250 ° F | -54 ... 121 ° C | [2] |
| Technical characteristics | |||
| supply voltage | 20 ... 30 V DC | ||
| Constant current supply | 2 ... 20 mA | ||
| Bias voltage | 8 ... 14 V DC | ||
| discharging | ?150 s | ||
| electrical insulation | ?100.000.000 ? | ||
| physical properties | |||
| sensor element | quartz | ||
| housing material | stainless steel | ||
| seal | epoxy resin | ||
| Size - Width | 0.67 in | 17 mm | |
| Size - Length | 1.725 in | 43.8 mm | |
| Size - Height | 0.6 in | 15 mm | |
| Weight (without cable) | 2.0 oz | 58 grams | [2] |
| electrical connection | integrated cable | ||
| cable outlet | Laterally | ||
| attachment | Through Hole | ||
| mounting torque | 7.38 ft-lb | 10 Nm | |
| Hints | |||
| [1] | Based upon a sensitivity of 10 mV / ?? | ||
| [2] | typically, | ||
| [3] | calculated based on the discharge time | ||
| [4] | Zero-based line of best fit, determined by the method of least squares | ||
| [5] | Details: see PCB Declaration of Conformance PS023 | ||
| included supply | |||
| M081A100 | Flathead screw M6 x 1 with Allen | -1 |