PCB-3503A1060KG
| basic data | |||
| sensitivity (at 10 V DC supply voltage) (±50%) | 0.003 mV / g | 0.0003 mV/(m/s²) | [1] |
| sensitivity | 0.0003 mV / V / g | 0,00003 mV/V/(m/s²) | [7] |
| Range | ±60. 000 g | ±588. 400 m/s² pk | |
| frequency range (1 dB) | 0 … 10,000 Hz | ||
| Resonance frequency | ? 120,000 Hz | ||
| damping rate | 2% crit chance | [3] | |
| Linearity error | ≤1% | ||
| transverse acceleration sensitivity | ≤ 3 | ||
| conditions | |||
| Overload limit (Shock) | ±80. 000 g pk | ±784. 532 m/s² pk | [2] |
| Overload limit (mechanical stop) | ≥80,000 g | ? 782.534 m/s² pk | |
| temperature range (storage) | -65 … 250 ° F | -54 … 121 ° C | |
| temperature range (operation) | -65 … 250 ° F | -54 … 121 ° C | |
| Temperature coefficient of sensitivity | -0.11 %/°F | -0.20 %/°C | [3] |
| Max thermal offset shift | ±10 mV | [4] | |
| Strain sensitivity (base area) | 0,3 g/µε | 2.94 (m/s²)/µε | [3] |
| specifications | |||
| power supply voltage (max) | 15.0 V DC | ||
| power | < 12 mA | ||
| input resistance (±700 Ω) | 2,000Ω | [1] | |
| output impedance (kΩ ±2) | 6,000Ω | [1] | |
| Spannungsoffset | 40 … 40 mV DC | [1] | |
| settling time | 0.01 s | [5] | |
| electrical insulation (housing) | ≥100 MΩ | [6] | |
| PhysicalProperties | |||
| sensor element | Piezoresistive MEMS element | ||
| geometry of the sensor element | Active bridge circuit | ||
| Housing material | titanium | ||
| waterproofing | epoxy resin | ||
| size - height | 0.25 in | 6.35 mm | |
| size - length | 0.47 in | 11.81 mm | |
| size - width | 0.47 in | 11.81 mm | |
| Dimensions (without cable) | 0.1 oz | 2.83 grams | [3] |
| electrical connection | integrated cable | ||
| connection position | Side | ||
| cord type | type 026, 8-conductor shielded PTFE cable | ||
| cable termination | tinned ends | ||
| Cable length | 10 ft | 3 m | |
| mounting | two mounting holes | ||
| Assembly torque | 8 in-lb | ||
| Notes | |||
| [1] | proSensor checked and documented on calibration certificate supplied with | ||
| [2] | a half-sine pulse ≤ 20 µs | ||
| [3] | Typically | ||
| [4] | -54 … 121 ° C, reference 24 ° C | ||
| [5] | settling time is the time the sensor signal maximum ben ötigt, after the supply voltage is applied the zero point on ±2% of the output span towards. The mounting surface must be located in the thermal balance. | ||
| [6] | Pro sensor tested to ensure compliance with the specification | ||
| [7] | Temperature coefficient of sensitivity is proportional to the applied supply voltage and can use a different voltage than at the calibration (10 V DC) are calculated from the calibration data. The possible measurement error increases with minimal (around0.5%). | ||
| Equipment | |||
| 081A114 | mounting screw and washer (4-40 x 3/8 "SHCS) | 2 | |
| ACS-62 T | Calibration of Triaxial Piezoresistive shock sensors | -1 |