PCB-3501A1220KG
| basic data | |||
| sensitivity (at 10 V DC supply voltage) (±50%) | 0.010 mV / g | 0.001 mV/(m/s²) | [1] |
| sensitivity | 0.001 mV / V / g | 0.0001 mV/V/(m/s²) | |
| range | ±20. 000 g | ±196.100 m/s² pk | |
| Frequency range (1 dB) | 0 … 10,000 Hz | ||
| resonance frequency | > 60,000 Hz | ||
| damping rate | 5% critical | [4] | |
| linearity | ≤1% | ||
| transverse acceleration sensitivity | ≤3% | ||
| Conditions of use | |||
| Overload limit (shock) | ±60. 000 g pk | ±588. 000 m/s² pk | [2] [3] |
| Overload limit (mechanical stop) | ≥30,000 g | ≥294.200 m/s² pk | |
| temperature range (operation) | 65 …250 ° F | -54 … 121 ° C | |
| Temperature coefficient of sensitivity | -0.11 %/°F | -0.20 %/°C | [4] |
| maximum thermal Offset offset | ±10 mV | [5] | |
| strain sensitivity (footprint) | 0.10 g/µε | 0.98 (m/s²)/µε | [4] |
| Magnetic sensitivity | 10 | µg/Gs/0.98 (m/s²) / T | [4] |
| technical characteristics | |||
| supply voltage (max) | 15.0 V DC | ||
| Power | < 3 mA | ||
| input impedance (kΩ ±2) | 6,000Ω | [1] | |
| Output impedance (±2 k Ω) | 6,000Ω | [1] | |
| Spannungsoffset | 40 … 40 mV DC | [1] | |
| settling time | 0.01 s | [6] | |
| electrical insulation (housing) | ≥100 MΩ | [3] | |
| physical properties | |||
| Sensor element | Piezoresistive MEMS element | ||
| geometry of the sensor element | Active bridge circuit | ||
| go äusematerial | titanium | ||
| waterproofing | epoxy resin | ||
| size - hex | 3/8 in | 9.5 mm | |
| Size - height | 0.50 in | 12.7 mm | |
| dimensions (without cable) | 0.088 oz | 2.5 grams | [4] |
| Electrical connection | integrated cable | ||
| connection position | side | ||
| cable type | type 034, 4-conductor shielded cable | ||
| Cable termination | tinned ends | ||
| cable length | 10 ft | 3 m | |
| mounting | Fixed external thread | ||
| mounting thread | 1/4 "-28 thread | ||
| notes | |||
| [1] | gepr Pro sensor" üft and documents calibration certificate supplied with | ||
| [2] | perioda half-sine pulse, ≤ 20 µs | ||
| [3] | Pro sensor tested to ensure compliance with the specification | ||
| [4] | Typically | ||
| [5] | -54 … 121 ° C, reference 24 ° C | ||
| [6] | settling time is the time the the Sensor signal maximum needed to relax after the supply voltage is applied the zero point on ±2% of the output span towards. The mounting surface must be located in the thermal balance. | ||
| Accessories | |||
| ACS-62 | calibration of Piezoresistive shock sensors | -1 | |
| (M) metric mounting | |||
| mounting thread | M6 x 0.75 male |