PCB-EX357E90
    zoom_out_map

      PCB-EX357E90

      • With ATEX / IECEx / CSA approval
      • Vibration sensor with charge output
      • Continuous operating temperature up to 649 ° C
      • With through hole
      • Measuring range 1,000 g
      • Sensitivity 5 pC / g
      • Upper limit frequency 2,500 Hz
      • Integrated hardline connection cable, length 3 meters,
        ending on 10-32 socket
      • New: slim 10-32 socket (diameter 6.35 mm)
      specifications
      basic dataEnglish unitsSI units 
      Sensitivity (± 10%)5 pC/g0,51 pC/(m/s²)
      measuring range± 1,000 g pk±9.800 m/s²pk
      Upper cutoff frequency (± 5%)2.500 Hz
      Upper limit frequency (± 1 dB)4.000 Hz
      resonant frequency≥14.000 Hz
      Linearity error (based on the entire measuring range)≤2,5 %
      Lateral acceleration sensitivity≤5 %
      Operating conditions
      Overload limit (shock)± 2,000 g pk±19.600 m/s²pk
      Temperature range (operation)-67 … 1.200 °F-55 … 649 °C
      Temperature range (load limit)-67 … 1.400 °F-55 … 760 °C
      Temperature range (connector)-67 … 900 °F-55 … 482 °C
      Maximum radiation exposure (Integrated Neutron Flux)10.000.000.000 N/cm²
      Maximum radiation exposure (Integrated Gamma Flux)100,000,000 rad
      Maximum radiation conditions (ATEX approval)II 1 G Ex ia lIC T6… 770 ° C Ga
      II 3 G Ex nA llC T6… 770 ° C Gc
      0 ° C <Tamb <+755 ° C
      Maximum radiation conditions (IECEx approval)Ex ia lIC T6 … 770 °C Ga
      Ex nA llC T6 … 770 °C Gc
      -55 °C < Tamb < +755 °C
      Maximum radiation conditions (approval ELT)Class I, Division 1, Groups A-D
      Class I, Zone 0, AEx ia IIC T6 … 770 °C Ga
      Class I, Division 2, Group A, B, C, D
      Class I, Zone 2, AEX nA IIC T6 … 770 °C Gc
      -55 °C ≤ Tamb ≤ +755 °C
      Technical characteristics
      capacity990 pF[2][1]
      Insulation resistance (at 649 ° C)≥10 kΩ
      Insulation resistance (at 21 ° C)≥100 MΩ
      Electrical insulationSignal isolated from the case
      Physical properties
      sensor elementUHT-12™
      Geometry of the sensor elementScherprinzip
      housing materialInconel
      Sealing (sensor housing)Hermetically sealed
      Sealing (connector)Hermetically sealed
      Size - height0,66 in16,7 mm
      Size - length1,16 in29,5 mm
      Size - width0,66 in16,7 mm
      Mass (without cable)1,8 oz50 grams[1]
      Electrical connectionIntegrated hardline cable
      cable length10 ft3 m
      cable termination10-32 coaxial
      attachmentThrough Hole

      Hints
      [1]typically,
      [2]Plus approx. 330 pF per additional meter of cable

      included supply
      081C108Montageschraube, 1/4"-28 x 1" lang, Inconel(1)
      ACS-1Frequency response, traceable to NIST (10 Hz to the upper 5% point)(1)
      PCB-EX357E90

      Specific References

      Download

      EX357E90_specs

      Download (115.78k)

      EX357E90_drawing

      Download (95.17k)