PCB-EX357E90
- With ATEX / IECEx / CSA approval
- Vibration sensor with charge output
- Continuous operating temperature up to 649 ° C
- With through hole
- Measuring range 1,000 g
- Sensitivity 5 pC / g
- Upper limit frequency 2,500 Hz
- Integrated hardline connection cable, length 3 meters,
ending on 10-32 socket - New: slim 10-32 socket (diameter 6.35 mm)
specifications | |||
---|---|---|---|
basic data | English units | SI units | |
Sensitivity (± 10%) | 5 pC/g | 0,51 pC/(m/s²) | |
measuring range | ± 1,000 g pk | ±9.800 m/s²pk | |
Upper cutoff frequency (± 5%) | 2.500 Hz | ||
Upper limit frequency (± 1 dB) | 4.000 Hz | ||
resonant frequency | ≥14.000 Hz | ||
Linearity error (based on the entire measuring range) | ≤2,5 % | ||
Lateral acceleration sensitivity | ≤5 % | ||
Operating conditions | |||
Overload limit (shock) | ± 2,000 g pk | ±19.600 m/s²pk | |
Temperature range (operation) | -67 … 1.200 °F | -55 … 649 °C | |
Temperature range (load limit) | -67 … 1.400 °F | -55 … 760 °C | |
Temperature range (connector) | -67 … 900 °F | -55 … 482 °C | |
Maximum radiation exposure (Integrated Neutron Flux) | 10.000.000.000 N/cm² | ||
Maximum radiation exposure (Integrated Gamma Flux) | 100,000,000 rad | ||
Maximum radiation conditions (ATEX approval) | II 1 G Ex ia lIC T6… 770 ° C Ga II 3 G Ex nA llC T6… 770 ° C Gc 0 ° C <Tamb <+755 ° C | ||
Maximum radiation conditions (IECEx approval) | Ex ia lIC T6 … 770 °C Ga Ex nA llC T6 … 770 °C Gc -55 °C < Tamb < +755 °C | ||
Maximum radiation conditions (approval ELT) | Class I, Division 1, Groups A-D Class I, Zone 0, AEx ia IIC T6 … 770 °C Ga Class I, Division 2, Group A, B, C, D Class I, Zone 2, AEX nA IIC T6 … 770 °C Gc -55 °C ≤ Tamb ≤ +755 °C | ||
Technical characteristics | |||
capacity | 990 pF | [2][1] | |
Insulation resistance (at 649 ° C) | ≥10 kΩ | ||
Insulation resistance (at 21 ° C) | ≥100 MΩ | ||
Electrical insulation | Signal isolated from the case | ||
Physical properties | |||
sensor element | UHT-12™ | ||
Geometry of the sensor element | Scherprinzip | ||
housing material | Inconel | ||
Sealing (sensor housing) | Hermetically sealed | ||
Sealing (connector) | Hermetically sealed | ||
Size - height | 0,66 in | 16,7 mm | |
Size - length | 1,16 in | 29,5 mm | |
Size - width | 0,66 in | 16,7 mm | |
Mass (without cable) | 1,8 oz | 50 grams | [1] |
Electrical connection | Integrated hardline cable | ||
cable length | 10 ft | 3 m | |
cable termination | 10-32 coaxial | ||
attachment | Through Hole |
Hints | |||
---|---|---|---|
[1] | typically, | ||
[2] | Plus approx. 330 pF per additional meter of cable |
included supply | ||
---|---|---|
081C108 | Montageschraube, 1/4"-28 x 1" lang, Inconel | (1) |
ACS-1 | Frequency response, traceable to NIST (10 Hz to the upper 5% point) | (1) |