PCB-EX357A95
- With ATEX / IECEx / CSA approval
- Vibration sensor with differential charge output
- Measuring axis perpendicular to the mounting screw
- Continuous operating temperature up to 649 ° C
- With through hole
- Measuring range 1,000 g
- Sensitivity 3.3 pC / g
- Upper limit frequency 3,000 Hz
- Integrated hardline connection cable, length 3 meters,
ending on 7 / 16-27 2-pin
| specifications | |||
|---|---|---|---|
| basic data | English units | SI units | |
| Sensitivity (± 10%) | 3,3 pC/g | 0,34 pC/(m/s²) | |
| measuring range | ± 1,000 g pk | ±9.800 m/s²pk | |
| Upper cutoff frequency (± 5%) | 3 kHz | ||
| Upper limit frequency (± 1 dB) | 5 kHz | ||
| resonant frequency | ≥15.000 Hz | ||
| Linearity error (based on the entire measuring range) | ≤1,0 % | ||
| Lateral acceleration sensitivity | ≤5 % | ||
| Operating conditions | |||
| Overload limit (shock) | ± 2,000 g pk | ±19.600 m/s²pk | |
| Temperature range (operation) | -67 … 1.200 °F | -55 … 649 °C | |
| Temperature range (load limit) | -67 … 1.400 °F | -55 … 760 °C | |
| Temperature range (connector) | -67 … 900 °F | -55 … 482 °C | |
| Maximum radiation exposure (Integrated Neutron Flux) | 10.000.000.000 N/cm² | ||
| Maximum radiation exposure (Integrated Gamma Flux) | 100,000,000 rad | ||
| Maximum radiation conditions (ATEX approval) | II 1 G Ex ia lIC T6… 770 ° C Ga II 3 G Ex nA llC T6… 770 ° C Gc 0 ° C <Tamb <+755 ° C | ||
| Maximum radiation conditions (IECEx approval) | Ex ia lIC T6 … 770 °C Ga Ex nA llC T6 … 770 °C Gc -55 °C < Tamb < +755 °C | ||
| Maximum radiation conditions (approval ELT) | Class I, Division 1, Groups A-D Class I, Zone 0, AEx ia IIC T6 … 770 °C Ga Class I, Division 2, Group A, B, C, D Class I, Zone 2, AEX nA IIC T6 … 770 °C Gc -55 °C ≤ Tamb ≤ +755 °C | ||
| Technical characteristics | |||
| capacity | 520 pF | [3][2][1] | |
| Insulation resistance (at 649 ° C) | ≥10 kΩ | ||
| Insulation resistance (at 21 ° C) | ≥100 MΩ | ||
| Electrical insulation | Signal isolated from the case | ||
| Physical properties | |||
| sensor element | UHT-12™ | ||
| Geometry of the sensor element | Scherprinzip | ||
| housing material | Differential | ||
| Sealing (sensor housing) | Hermetically sealed | ||
| Sealing (connector) | Hermetically sealed | ||
| Size - height | 0,56 in | 14,2 mm | |
| Size - length | 0,95 in | 24,1 mm | |
| Size - width | 0,56 in | 14,2 mm | |
| Mass (without cable) | 1,6 oz | 45 grams | [1] |
| Electrical connection | Integrated hardline cable | ||
| cable length | 10 ft | 3,05 m | |
| cable termination | 7/16-27 2-Pin | ||
| attachment | Through Hole | ||




| Hints | |||
|---|---|---|---|
| [1] | typically, | ||
| [2] | Plus approx. 100 pF per additional meter of cable | ||
| [3] | Plus approx. 50 pF per additional meter of cable | ||
| included supply | ||
|---|---|---|
| 081A116 | Mounting screw, 10-32 UNJF-3A, length 5/8 ", Inconel 718 | (1) |
| ACS-1 | Frequency response, traceable to NIST (10 Hz to the upper 5% point) | (1) |