PCB-357E92
- Vibration sensor with charge output, li >
- Continuous use temperature up to 649 ° C,
- With drill through, li >
- Measuring range 1000 g, li >
- Sensitivity 2.3 pC/g,.
- Upper cutoff frequency 2.500 Hz, li >
- Integrated hardline cable, length 3 m,
ending on 10-32 socket, li > - New: Slim 10-32 socket (diameter 6. 35 mm)
< tr>Maximum exposure (integrated neutron flux)10.000.000.000 N / cm²
Specifications | |||
---|---|---|---|
Basic data | English units | SI units | |
Sensitivity (±10 %) | 2.3 pC/g | 0.23 pC/(m/s²) | |
Measuring range | ±1.000 gPK | ±9.800 m/s²PK | |
Upper frequency limit (≤5 %) | 2.500 Hz | ||
Upper cutoff frequency (±1 dB) | 4.000 Hz | ||
Resonance frequency | ≥15.000 Hz | ||
Linearity error (based on total measuring range) | ≤2,5 % | ||
Transverse acceleration sensitivity | ≤5 % | ||
Conditions of use | |||
Overload limit (shock) | ±2.000 gPK | ±19.600 m/s²PK | |
Temperature range (operation) | -67... 1200 °F | -55... 649 ° C | |
Temperature range (load limit) | -67... 1,400 ° F | -55... 760 ° C | |
Temperature range (connector) | -67... 900 ° F | -55... 482 ° C | |
Maximum exposure (integrated gamma flux) | 100,000,000 wheel | ||
Technical characteristics | |||
capacity | 1,000 pF | [2] [1] | |
Isolation resistance (at 649 ° C) | ≥10 kΩ | ||
Isolation resistance (at 21 ° C) | |||
Output polarity | Negative | [3] | |
Electrical insulation | Signal from the housing isolated | ||
Physical properties | |||
Sensor element | UHT-12™ | ||
Geometry of the sensor element | Shear principle | ||
Housing material | Inconel | ||
Sealing (sensor housing) | Hermetic | ||
Sealing (connector) | Hermetically sealed welded | ||
Size - height | 0.56 in | 14.2 mm | |
Size - length | 0.95 in | 24.1 mm | |
Size - width | 0.56in | 14.2 mm | |
Weight (without cable) | 1.6 oz | 45 grams | [1] |
Electrical connection | Integrated hardline cable | ||
Cable length | 10 ft | 3 m | |
Cable termination | 10-32-coaxial socket | ||
Fixing | Through hole |
Notes | |||
---|---|---|---|
[1] | Typically | ||
[2] | Plus approx. 330 pF per additional meter cable | ||
[3] | Negative signal for positive acceleration |
Included accessories | ||
---|---|---|
081A116 | Mounting screw, 10-32 UNJF-3A, length 5/8 ", Inconel 718 | (1) |
ACS-1 | Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt) | (1) |