PCB-66212APZ1
    zoom_out_map

      PCB-66212APZ1

    • ICP® vibration sensor for OEM applications,
    • TO-5 package,
    • Suitable for PCB mounting,
    • Measurement range 50 g,
    • Sensitivity 100 mV/g,
    • Frequency range 0.5 … 10,000 Hz,
    • One-point calibration at 100 Hz,
    • Connection pins below
    • basic data
      sensitivity (±20%)100 mV/g10.2 mV/(m/s²)[1] [2]
      measuring range50 Ω490 m/s²
      Frequency range (± 3 dB)0,5 … 10,000 Hz[3] [6]
      resonance frequency> 25,000 Hz[3]
      Wide band resolution350 µg RMS3.434 µm / s ² RMS[5]
      linearity error≤ 1%[4]
      transverse acceleration sensitivity≤ 7%
      conditions
      Overload limit (shock)5,000 g pk49,050 m/s² pk
      temperature range (operation)65 … 185 ° F-54 … 84 ° C
      technical characteristics
      settling time (on bias voltage ± 1%)≤ 2 s
      Discharge charge time constant≥ 0.3 s
      Power18 … 28 V DC
      constant power supply2 … 20 mA
      Output impedance< 150 Ω
      bias voltage (±10%)8 … 12 V DC
      Spectral noise (10 Hz)8 µg / √ Hz78,50 (µm / s ²) / √ Hz[5]
      spectral noise (100 Hz)5 µg /. √ Hz49,1 (µm / s ²) / √ Hz[5]
      spectral noise (1,000 Hz)4 µg / √ Hz39.2 (µm / s ²) / √ Hz[5]
      -physical Properties
      size - diameter of the footprint0.36 in9.1 mm
      size - height0.38 in9.7 mm
      Mass0.01 oz3 grams
      attachmentBonding/soldering
      sensor elementceramic
      Geometry of the sensor elementShear principle
      Housing materialstainless steel
      sealinghermetically sealed welded
      Electrical connectionssoldering pins
      Connectiondown
      pin assigNment (pin 1)Signal/power
      pin assigNment (pin 2) Mass
      pin assigNment (PIN 3)no function
      notes
      [1]conversion factor 1 g = 9.81 m/s²
      [2]positive output signal during acceleration in Z-direction < br(bei Lötmontage: positives Ausgangssignal bei Beschleunigung nach oben)
      [3] Depending on the installation
      [4]zero-based balancing line, determined using the method of least squares
      [5] Typically
      [6]the upper cut-off frequency tolerance: ±10%
      [7]details: see PCBs Declaration of conformance PS023 and PS060
      Accessories
      ICS-2single point calibration at 100 Hz (traceable to NIST)-1
      (HT) high temperature electronics
      temperature range (operation)-65 … 250 ° F-54 … 121 ° C
      PCB-66212APZ1

      Specific References

      Download

      66212APZ1_manual.PDF

      Operating instructions

      Download (529.9k)

      66212APZ1_specs.PDF

      Technical data sheet