PCB-(M)605B02
zoom_out_map

PCB-(M)605B02

  • Biaxialer industrial ICP® vibration sensor,
  • With through hole,
  • Measuring range 10 g,
  • Sensitivity500 mV / g,
  • Frequency range 0.5 … 3,000 Hz,
  • One-point calibration at 100 Hz,
  • 3-pin female connector on the side
  • "
    basic data
    sensitivity (±20%) 500 mV / g 51 mV/(m/s²) [5]
    measuring range ± 10 g ±98 m / s²
    Frequency range (± 3 dB) 30 … 180,000 cpm 0.5 … 3,000 Hz [2]
    resonance frequency 600 kcpm 10,000 Hz [1]
    Wide band resolution 150 µg 1,471 µm / s ² [1]
    linearity ≤1% [3]
    Transverse acceleration sensitivity ≤ 5%
    Conditions of use
    Overload limit (shock) 5,000 g pk 49,050 m/s² pk
    Temperature range -65 … 250 ° F -54 … 121 ° C
    protection class IP68
    Technical characteristics
    settling time (on bias voltage ± 1%) ≤ 5.0 s
    discharging charging time constant ≥ 0.3 s
    Power 18 … 28 V DC
    constant power supply 2 … 20 mA
    Output impedance < 500 Ω
    Bias voltage 8 … 12 V DC
    Spectral noise (10 Hz) 8 µg / √ Hz 78.5 (µm / s ²) / √ Hz [1]
    spectral noise (100 Hz) 3 µg / √ Hz 29.4 ( µm / s ²) / √ Hz [1]
    spectral noise (1,000 Hz) 3 µg / √ Hz 29.4 (µm / s ²) / √ Hz [1]
    electrical insulation (Housing) ≥ 100 MΩ
    Physical properties
    size - diameter 1.38 in 34.9 mm
    size - height 1.00 in 25.4 mm
    Dimensions (without cable) 3.9 oz 110.6 grams
    mounting thread 1/4 "-28 UNF no equivalent [4]
    Assembly torque 2 … 5 ft-lb 2.7 … 6.8 Nm
    sensor element ceramic
    geometry of the Sensor element shear principle
    housing material stainless steel
    sealing hermetically sealed welded
    Electrical connection 3-Pin MIL-C-5015
    connection position side
    Pin assigNment (PIN A) x
    pin assigNment (PIN B) Z axis
    pin assigNment (PIN C) dimensions
    Notes
    [1] typically
    [2] the upper cut-off frequency tolerance: ±10%
    [3] zero-based balancing line, determined using the method of least squares
    [4] mounting with M6 screw possible
    [5] conversion factor = 1 g9.81 m/s²
    [6] details: see PCBs Declaration of conformance PS023
    equipment
    081A68 Mounting screw 1/4 "-28 x 0.9" -1
    ACS-2 T single point calibration at 100 Hz (traceable to NIST) for each axis in -1
    (M) metric Assembly
    equipment
    M081A68 metric mounting bolt with M6 thread -1
    PCB-(M)605B02

    Specific References

    Download

    605B02_drawing.PDF

    Technical drawing

    Download (75.6k)

    605B02_manual.PDF

    Operating instructions

    Download (832.91k)

    605B02_specs.PDF

    Technical data sheet

    Download (460.89k)