PCB-EX(M)639A91
    zoom_out_map

      PCB-EX(M)639A91

      • Triaxial industrial ICP® vibration sensor, 
      • With through hole, 
      • Measuring range 50 g, 
      • Sensitivity 100 mV / g, 
      • Frequency range 0.5 ... 10.000 Hz, 
      • Frequency calibration, 
      • M12 connection socket on the side
      specifications
      basic dataEnglish unitsSI units 
      Sensitivity (± 10%)100 mV/g10,2 mV/(m/s²)[1]
      measuring range± 50 g pk±491 m/s² pk
      Frequency range (± 5%)8,0 … 5.500 Hz
      Frequency range (± 3 dB)0,5 … 10.000 Hz
      resonant frequency≥25.000 Hz
      Broadband resolution (1 ... 10,000 Hz)0,0003 g rms0,003 m/s² rms[2]
      linearity error≤1 %[3]
      Lateral acceleration sensitivity≤5 %
      Operating conditions
      Overload limit (shock)± 5.000 g pk
      Temperature range (operation)-65 … 250 °F-54 … 121 °C
      Temperature influence on the sensitivitySee curve below[2]
      Technical characteristics
      supply voltage18 … 30 VDC
      Constant current supply2… 20 mA
      output impedance≤150 Ω
      Bias voltage8 … 12 VDC
      discharging≥0,32 s
      Settling time (within ± 10% of the bias voltage)<2 s
      Spectral noise (1 Hz)90 µg/√Hz883 (µm/s²)/√Hz[1][2]
      Spectral noise (10 Hz)20 µg/√Hz196 (µm/s²)/√Hz[1][2]
      Spectral noise (100 Hz)10 µg/√Hz98,1 (µm/s²)/√Hz[1][2]
      Spectral noise (1,000 Hz)3,0 µg/√Hz29,4 (µm/s²)/√Hz[1][2]
      Electrical insulation (housing)≥100 MΩ
      Physical properties
      sensor elementceramics
      Geometry of the sensor elementScherprinzip
      housing materialstainless steel
      sealHermetically sealed
      Size - height0,72 in18,3 mm
      Size - length0,95 in24,1 mm
      Size - width0,95 in24,1 mm
      Mass (maximum)3,0 oz85 grams[2]
      Electrical connection4-pin connector M12
      port locationLaterally
      attachmentThrough Hole

      16884_16.gifcenelec.gifCEMark.gif[4]

      Hints
      [1]Conversion factor 1 g = 9,81 m / s²
      [2]typically,
      [3]Zero-based balancing line, determined by the least squares method
      [4]Details: siehe PCB Declaration of Conformance PS023

      included supply
      081A56Montageschraube 1/4"-28 x 0,75"(1)
      ACS-1TFrequency response for triaxial transducers, traceable to NIST, 10 Hz to the upper 5% frequency(1)
      PCB-EX(M)639A91

      Specific References

      Download

      639A91_drawing.PDF

      Technical drawing

      Download (87k)

      639A91_manual.PDF

      Manual

      Download (859.85k)

      639A91_specs.PDF

      Specifications

      Download (76k)