TMS-2110E
    zoom_out_map

      TMS-2110E

      • Dual purpose Shaker
      • For the modal analysis as well as for part / component test
      • Maximum force 489 N
      • Frequency range 0... 6,500 Hz
      • Stroke 25 mm

      specifications
      Basic dataEnglish unitsSI units
      pk max force, sine
      (bei manueller Kühlung)
      110 lbf489 N[1] [5]
      maximum force, random vibration RMS
      (bei manueller Kühlung)
      45 lbf334 N[1] [5]
      pk max force, shock
      (50 ms)
      110 lbf489 N
      hub pk-pk, constant stimulation1.0 in25.4 mm
      Stroke, clipping area1.03 in26.2 mm
      nominal frequency range0... 6,500 Hz[2]
      Basic resonance> 4,000 Hz[2]
      maximum vibration velocity70 in / s pk1.8 m/s pk
      Maximum acceleration amplitude
      (keine Last)
      110 g pk1,086 m/s² pk
      maximum acceleration amplitude
      (0,45 kg Last)
      55 g pk540 m/s² < sMall > pk
      maximum acceleration amplitude
      (2,3 kg Last)
      18 g pk177 m/s² pk
      maximum acceleration amplitude
      ( Resonance)
      150 g pk1.472 m/s² pk
      maximum acceleration amplitude
      (Schock Spitze)
      1.962 m/s² pk
      Typical maximum payload10 lb4.5 kg
      physical properties
      thread in the anchor plate5 x 10-32[3]
      Ankermasse0,454 kg1 lb
      Stiffness of the suspension90 lbf / in15.8 N/mm
      Nominal drive current
      (bei manueller Kühlung)
      22 A RMS
      Magnetic stray field,
      38 mm above the head plate
      < 20 Gauss>0.002 Tesla
      Magnetic stray field,
      25 mm next to the housing
      < 25 Gauss>0.0025 Tesla
      Manual coolingair: 100 cfm
      water: 15 cfm
      air: 170 m³/h
      water: 25.5 m ³/h
      [5]
      Nominal dimensions
      (Höhe x Breite x Tiefe)
      11.7 x 12.5 x 6.5 in297 x 318 x 165 mm[4]
      nominal weight56 lb25 kg
      temperature40... 100 ° F,
      < 85% RH
      4... 38 ° C,
      < 85% RH
      power12 V DC, 12 A DC[5]

      Notes
      [1]for the use of the maximum force of the Shaker with a TMS-2050E09 power amplifier must be fed and manually cooled.
      [2]Lastabhängig; the specified values apply when no load.
      [3]Chuck adapter for attachment of Stingers in the scope of delivery included
      [4]exact dimensions: see technical drawing in the data sheet
      [5]required for operation: power amplifier TMS-2050E09-FS and cooling Kit TMS-2000 X 04

      included supply
      baseMounting base EasyTurn ™-suspension, allows aligNment of the shaker in the direction of the excitation point(1)
      Electric wireShaker cable, length 2.4 m(1)
      2000X03Accessory Kit (includes suitcases, Stinger, chuck adapter, allen wrench, spare fuse and other accessories)(1)