PCB-352A71

PCB-352A71

  • ICP®-miniature vibration sensor,
  • Mass 0.64 grams,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • ,
  • frequency range 0.5 … 10,000 Hz,
  • integrated cable, length 3 m,
    ending on 10-32 plug
  • basic data
    sensitivity (±15%)10 mV / g1.02 mV/(m/s²)
    range±500 g pk ±4. 900 m/s² pk
    frequency range (±5%)0.5 … 10,000 Hz
    Frequency range (± 10%)0.35 … 16,000 Hz
    frequency range (± 3 dB)0.2 … 25,000 Hz
    Resonance frequency≥ 65,000 Hz
    wide band resolution0.003 g RMS0.03 m/s² RMS[1]
    Linearity≤ 1%[2]
    transverse acceleration sensitivity≤ 5%
    conditions of use
    (Shock) overload limit± 10.000 g pk±98. 000 m/s² pk
    Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
    Specifications
    power supply18 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤200Ω
    Bias voltage7 … 11 V DC
    Discharging charging time constant1.0 … 3<5 s
    settling time < br(auf Bias-Spannung ±10 %)≤ 3 s
    Spectral noise (1 Hz)725 µg / √ Hz7.110 (µm / s ²) / √ Hz[1]
    spectral noise (10 Hz)225 µg / √ Hz2.210 ( µm / s ²) / √ Hz[1]
    spectral noise (100 Hz)60 µg / √ Hz590 (µm / s ²) / √ Hz[1]
    spectral noise ( 1,000 Hz)20 µg / √ Hz196 (µm / s ²) / √ Hz[1]
    physical properties
    Size - height0.14 in3.6 mm
    Dimensions (without cable)0.023 oz0.64 grams[1]
    sensor elementceramic
    geometry of the sensor elementShear principle
    Housing materialtitanium
    sealinghermetically sealed
    size e length0.41 in10.4 mm
    size - width0.25 in6.4 mm
    wiringpins with soldered Cable
    cable exitside
    cable terminating resistance10-32-coaxial connector
    Cable length10 ft3 m[3]
    attachmentbonding
    notes
    [1]typically
    [2]zero-based balancing line, determined using the method of least squares
    [3]Composed of 30 cm cable type 089 (32 AWG, twisted pair) and 2.7 m coaxial cable type 018
    Equipment
    039A32transfer tool for the model 352A71-1
    080A109 Mounting wax-1
    ACS-1frequency response, traceable to NIST (10 Hz up to the upper 5% point)-1