PCB-352A56

PCB-352A56

  • ICP®-miniature vibration sensor,
  • Mass 1.8 grams,
  • With TEDS memory chip,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5 … 10,000 Hz,
  • 5-44 female connector on the side
  • basic data
    sensitivity (±10%)100 mV/g10.2 mV/(m/s²)
    range±50 g pk ±490 m/s 2 pk
    frequency range (±5%)0.5 … 10,000 Hz
    Frequency range (± 10%)0.3 … 15,000 Hz
    resonance frequency≥ 45,000 Hz
    wide band resolution0.0006 g RMS0.006 m/s² RMS[1]
    linearity≤ 1%[3]
    transverse acceleration sensitivity≤ 5%
    TEDS Chipintegrated by default[2]
    Conditions of use
    Overload limit (shock)±5. 000 g pk±49. 050 m/s² pk
    Temperature range(Operation)-65 … 250 ° F-54 … 121 ° C
    Specifications
    power supply22 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤200Ω
    Bias voltage8.5 … 15.5 V DC
    Discharging charging time constant0.5 … 1<5 s
    settling time < br(auf Bias-Spannung ±10 %)<5 s
    Spectral noise (1 Hz)120 µg / √ Hz1,180 (µm / s ²) / √ Hz[1]
    spectral noise (10 Hz)40 µg / √ Hz392 ( µm / s ²) / √ Hz[1]
    spectral noise (100 Hz)30 µg / √ Hz294 (µm / s ²) / √ Hz[1]
    spectral noise ( 1,000 Hz)10 µg / √ Hz98.1 (µm / s ²) / √ Hz[1]
    physical properties
    size-Height0.26 in6.6 mm
    mass0.06 oz1.8 grams[1]
    sensor elementceramic
    Geometry of the sensor elementshear principle
    housing materialtitanium
    sealinghermetically sealed
    Size - length0.57 in14.5 mm
    size - width0.30 in7.6 mm
    Electrical connection5-44 coaxial
    connection positionside
    attachmentbonding
    Notes
    [1]typically
    [2]TEDS memory in accordance with IEEE PP1451. 4
    [3]zero-based balancing line, determined using the method of least squares
    [4]details: see PCBs Declaration of conformance PS023
    Accessories