PCB-352A24/NC

PCB-352A24/NC

  • ICP®-miniature vibration sensor,
  • Mass 0.8 grams.
  • Mass-insulated,.
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 1... 8,000 Hz,
  • 3-56 female connector on the side.
  • Without cable

 

Basic data
Sensitivity (±10 %)10.2 mV/(m/s²) 
 
Measuring range±50 gPK±490 m/s²PK 
 
Frequency range (≤5 %)1.0... 8,000 Hz  
 
Frequency range (±10 %)0.8... 10,000 Hz  
 
Frequency range (± 3 dB)0.4... 12,000 Hz  
 
Resonance frequency≥30.000 Hz  
 
Wide band resolution0.0002 g RMS0,002 m/s² RMS[1]
 
Linearity error±1 % [2]
 
Transverse acceleration sensitivity≤5 %  
Conditions of use
Overload limit (shock)±5.000 gPK±49.050 m/s²PK  
temperature range (operation)-65... 250 ° F-54... 121 ° C 
specifications
power supply18... 30 V DC  
 
constant power supply2... 20 mA  
 
output impedance≤300Ω  
 
Bias voltage8... 12 V DC  
 
discharging charging time constant0,4 … 1,5 s  
 
settling time
(auf Bias-Spannung ±10 %)
>8 s  
 
spectral noise (1 Hz)80 µg/√Hz785 (µm/s²)/√Hz 
 
Spectral noise (10 Hz)15 µg/√Hz147 (µm/s²)/√Hz[1]
 
spectral noise (100 Hz)4 µg/√Hz39 (µm/s²)/√Hz[1]
 
Spectral noise (1,000 Hz)1 µg/√Hz9.8 (µm/s²)/√Hz[1]
 
Electrical insulation (base)≥100 MΩ 
Physical properties
Size - height0.19 in4.8 mm 
 
Size - length0.48 in12.2 mm 
 
Size - width0.28 in7.1 mm 
 
Mass0.03 oz0.8 grams[1]
 
Sensor elementCeramic  
 
Geometry of the sensor elementShear principle  
 
Housing materialAnodized aluminium  
 
SealingEpoxy resin  
 
Electrical connection3-56 coaxial connector  
 
Connecting positionOn the side  
 
FixingAdhesive mounting  
Notes
[1]Typically  
 
[2]Zero-AusgleichsgeRade, determined using the method of least squares  
 
[3]Details: see PCBs Declaration of conformance PS023  
Included accessories
039A28Transfer tool-1 
 
080A109Mount wax-1 
 
ACS-1Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt)-1 

20 other articles of the same category: