PCB-(M)353B18
    zoom_out_map

      PCB-(M)353B18

      • ICP®-miniature vibration sensor,
      • Measuring range 500 g
      • Sensitivity 10 mV / g,.
      • Frequency range 1... 10,000 Hz,
      • Mass 1.8 grams.
      • 10-32 female connector above

       

      Basic data
      Sensitivity (±10 %)10 mV / g1.02 mV/(m/s²) 
       
      Measuring range±500 gPK±4.905 m/s²PK 
       
      Frequency range (≤5 %)1... 10,000 Hz  
       
      Frequency range (±10 %)0.7... 18,000 Hz  
       
      Frequency range (± 3 dB)0.35... 30,000 Hz  
       
      Resonance frequency≥70.000 Hz  
       
      Wide band resolution0.005 g RMS0.05 m/s² RMS[1]
       
      Linearity error±1 % [2]
       
      Transverse acceleration sensitivity≤5 % [3]
      Conditions of use
      Overload limit (shock)±10.000 gPK±98.100 m/s²PK 
       
      Temperature range (operation)-65... 250 ° F-54... 121 ° C 
       
      Strain sensitivity (footprint)≤0, 003 g/µε≤0. 03 (m/s²)/µε[1]
      Technical properties
      Supply voltage18... 30 V DC  
       
      Constant power supply2... 20 mA  
       
      Output impedance≤100 Ω  
       
      Bias voltage8... 12 V DC  
       
      Discharge charge time constant0.5... 2.0 s  
       
      Spectral noise (1 Hz)2,800 µg/√Hz27.468 (µm/s²)/√Hz[1]
       
      Spectral noise (10 Hz)700 µg/√Hz6.867 (µm/s²)/√Hz[1]
       
      Spectral noise (100 Hz)180 µg/√Hz1.766 (µm/s²)/√Hz[1]
       
      Spectral noise (1,000 Hz)64 µg/√Hz628 (µm/s²)/√Hz[1]
      Physical properties
      Size - height0.74 in18.8 mm 
       
      Size - hex9/32 in7.1 mm 
       
      Mass0.06 oz1.8 grams[1]
       
      Sensor elementQuartz  
       
      Geometry of the sensor elementShear principle  
       
      Housing materialTitanium  
       
      SealingHermetically sealed welded  
       
      Electrical connection10-32-coaxial socket  
       
      Connecting positionTop  
       
      Mounting thread5-40 male  
       
      Installation torque8... 12 in-lb90... 135 NCM 
      Notes
      [1]Typically  
       
      [2]Zero-balance just, determined using the method of least squares  
       
      [3]Transverse acceleration sensitivity typically ≤3%  
       
      [4]Details: see PCBs Declaration of conformance PS023  
      Included accessories
      080A109Mount wax-1 
       
      080A15Adhesive mounting-1 
       
      ACS-1Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt)-1 
      (M) metric mounting
      Mounting threadM3 x 0.50 male  
       
      Included accessories   
       
      M080A15Adhesive mounting-1 
      (A) bonding
      Included accessories   
       
      080A90Superglue-1 
      (B) reduced bias voltage
      Bias voltage4.5... 7,5 V DC  
       
      Supply voltage12... 30 V DC  
       
      Constant power supply1... 20 mA  
       
      Measuring range300 g PK2.943 m/s² PK 
      (J) mass insulation
      Frequency range (≤5 %)1... 8,000 Hz  
       
      Frequency range (±10 %)0.7... 15,000 Hz  
       
      Resonance frequency56,000 Hz  
       
      Electrical insulation  
       
      Size - hex3/8 in9.5 mm 
       
      Size - height0.82 in20.8 mm 
       
      Mass0.10 oz3.0 grams 
      (Q) increased discharge charge time constant
      Frequency range (≤5 %)0.15... 10,000 Hz  
       
      Frequency range (± 10%)0.1... 18,000 Hz  
       
      discharging charging time constant>  
       
      settling<  
       
      Accessories   
       
      ACS-97low frequency calibration of 1... 10 Hz-1 
      (W) waterproof cable connection
      connection positionabove  
      PCB-(M)353B18

      Specific References

      Download

      353B18_drawing.PDF

      Technical drawing

      Download (51.93k)

      353B18_manual.PDF

      Operating instructions

      Download (2.16M)

      353B18_specs.PDF

      Technical data sheet

      Download (511.64k)