PCB-352A26
- ICP®-miniature vibration sensor
- Mass 0.2 grams
- Mass-insulated
- Measuring range 500 g
- Sensitivity 10 mV / g
- Frequency range 2... 10,000 Hz
- 3-56 female connector on the side
- Including connection cable, length 3 m,
ending on 10-32 plug
,
Specifications | |||
---|---|---|---|
Basic data | English units | SI units | |
Sensitivity (±20 %) | 10 mV / g | 1.02 mV/(m/s²) | |
Measuring range | ±500 g pk | ±4.905 m/s² pk | |
Frequency range (≤5 %) | 2.0... 10,000 Hz | ||
Frequency range (±10 %) | 1.5... 15,000 Hz | ||
Frequency range (± 3 dB) | 0.7... 25,000 Hz | ||
Resonance frequency | ≥70.000 Hz | ||
Wide band resolution (1... 10,000 Hz) | 0.003 g rms | 0.03 m/s² rms | [2] |
Linearity error | ≤1 % | [1] | |
Transverse acceleration sensitivity | ≤5 % | ||
Conditions of use | |||
Overload limit (shock) | ±5.000 g pk | ±49.050 m/s² pk | |
Temperature range (operation) | -65... 250 ° F | -54... 121 ° C | |
Technical properties | |||
Supply voltage | 22... 30 V DC | ||
Konstantstromversorgung | 2... 20 mA | ||
output impedance | ≤100Ω | ||
Bias voltage | 9... 16 V DC | ||
discharging charging time constant | 0.24... 1,0 s | ||
settling time (auf Bias-Spannung ±10 %) | 3 s | ||
spectral noise (1 Hz) | 1,500 µg/√Hz | 14.715 (µm/s²)/√Hz | [2] |
spectral Noise (10 Hz) | 400 µg/√Hz | 3,924 (µm/s²)/√Hz | [2] |
spectral noise (100 Hz) | 120 µg/√Hz | 1,177 (µm/s²)/√Hz | [2] |
spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm/s²)/√Hz | [2] |
spectral noise (10,000 Hz) | 20 µg/√Hz | 196 (µm/s²)/√Hz | [2] |
electrical insulation (base) | ≥ 100 MΩ | ||
Physical properties | |||
size - height | 0.11 in | 2.8 mm | |
mass | 0.007 oz | 0.2 gm | [2] |
sensor element | ceramic | ||
Geometry of the sensor element | shear principle | ||
Housing material | Anodized aluminium | ||
Sealing | Epoxy resin | ||
Size - length | 0.34 in | 8.6 mm | |
Size - width | 0.16 in | 4.1 mm | |
Electrical connection | 3-56 coaxial connector | ||
Connecting position | On the side | ||
Fixing | Adhesive mounting |
Notes | |||
---|---|---|---|
[1] | Zero-balance just, determined using the method of least squares | ||
[2] | Typically | ||
[3] | Details: See PCBs Declaration of conformance PS023 |
Included accessories | ||
---|---|---|
030A10 | Coaxial cable, 3 m, 3-56-plug to 10-32 | (1) |
039A26 | Transfer tool | (1) |
080A109 | Mount wax | (1) |
ACS-1 | Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt) | (1) |