      • ICP®-miniature vibration sensor,
      • Measuring range 500 g
      • Sensitivity 10 mV / g,.
      • Frequency range 1... 10,000 Hz,
      • Mass 1.7 grams.
      • Integrated cable, length 3 m,
        ending on 10-32 plug
      basic data
      Sensitivity (± 10%)10 mV / g1.02 mV / (m / s)
      measuring range± 500 g pk± 4,905 m / s² pk
      Frequency range (± 5%)1 ... 10,000 Hz
      Frequency range (± 10%)0.7 ... 17,000 Hz
      Frequency range (± 3 dB)0.35 ... 30,000 Hz
      resonant frequency≥70.000 Hz
      Broadband resolution0.005 g RMS0.05 m / s RMS[1]
      linearity error≤1%[2]
      Lateral acceleration sensitivity≤5%[3]
      Operating conditions
      Overload limit (shock)± 10,000 g pk± 98,100 m / s² pk
      The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C
      Strain sensitivity (base surface)≤0,002 g / µε≤0,02 (m / s²) / µε[1]
      Technical characteristics
      supply voltage18 ... 30 V DC
      Constant current supply2 ... 20 mA
      output impedance≤100 Ω
      Bias voltage8 ... 12 V DC
      discharging0.5 ... 2.0 s
      Settling time 
      (on the bias voltage ± 10%)
      <5 s
      Spectral Noise (1 Hz)2800 µg/√Hz27,468 (µm/s²)/√Hz[1]
      Spectral noise (10 Hz)700 µg/√Hz6,867 (µm/s²)/√Hz[1]
      Spectral noise (100 Hz)180 µg/√Hz1,766 (µm/s²)/√Hz[1]
      Spectral noise (1,000 Hz)64 ug / √Hz628 (µm/s²)/√Hz[1]
      physical properties
      Size - Height0.59 in15.0 mm
      Size - Hexagon9/32 in7.1 mm
      Weight (without cable)0.06 oz1.7 grams[1]
      sensor elementquartz
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealHermetically sealed
      electrical connectionintegrated cable
      cable outletAbove
      cable termination10-32 coaxial connector
      cable length10 ft3 m
      cable typeType 031, twisted pair
      mounting thread5-40 male
      mounting torque8 ... 12 in-lb90 ... 135 Ncm
      Hints
      [1]typically,
      [2]Zero-based line of best fit, determined by the method of least squares
      [3]Lateral acceleration sensitivity typically ≤ 3%
      included supply
      080A109mounting wax-1
      080A15adhesive mounting-1
      ACS-1Frequency response, traceable to NIST (10 Hz up to the top 5% point)-1
      (M) Metric assembly
      mounting threadM3 x 0.50 male
      included supply
      M080A15adhesive mounting-1
      (A) adhesive mounting
      included supply
      080A90superglue-1
      (B) Reduced bias voltage
      Bias voltage4.5 ... 7.5 V DC
      supply voltage12 ... 30 V DC
      Constant current supply1 ... 20 mA
      measuring range300 g pk2,943 m / s pk
      (J) ground isolation
      Frequency range (± 5%)1 ... 8000 Hz
      Frequency range (± 10%)0.7 ... 15,000 Hz
      resonant frequency56,000 Hz
      electrical insulation?100 milliohms
      Size - Hexagon3/8 in9.5 mm
      Size - Height0.77 in19.6 mm
      Weight (without cable)0.10 oz2.9 grams
      (Q) Increased discharge time
      Frequency range (± 5%)0.15 ... 10,000 Hz
      Frequency range (± 10%)0.1 ... 17,000 Hz
      discharging?5 s
      settling<45 s
      included supply
      ACS-97Low-frequency calibration of 1 ... 10 Hz-1
      (W) Waterproof cable connection
      temperature range-20 ... 220 ° F-29 ... 104 ° C
      port locationAbove
      cable length10 ft3 m
      cable typeType 018, coaxial cable
      PCB-(M)353B17

      Specific References

      Download

      353B17_drawing.PDF

      Technical drawing

      Download (66.51k)

      353B17_manual.PDF

      Operating instructions

      Download (1.72M)

      353B17_specs.PDF

      Technical data sheet

      Download (32.41k)