PCB-(M)353B16

PCB-(M)353B16

  • ICP®-miniature vibration sensor,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 1 … 10,000 Hz,
  • Mass 1.5 grams,
  • 5-44 female connector above
  •  

    basic data
    sensitivity (±10%)10 mV / g1.02 mV/(m/s²) 
     
    range±500 g pk ±4. 905 m/s 2 pk 
     
    frequency range (±5%)1 … 10,000 Hz  
     
    Frequency range (± 10%)0.7 … 20,000 Hz  
     
    frequency range (± 3 dB)0.35 … 30,000 Hz  
     
    Resonance frequency≥70,000 Hz  
     
    wide band resolution0.005 g RMS0.05 m/s² RMS[1]
     
    Linearity≤1% [2]
     
    transverse acceleration sensitivity≤5% [3]
    conditions of use
    (Shock) overload limit± 10.000 g pk±98.100 m/s² pk 
     
    64 µg / √Hz628 (µm / s ²) / √Hz[1]
    physical properties
    size - height0.68 in17.3 mm 
     
    Size - Allen9/32 in7.1 mm 
     
    mass0.05 oz1.5 grams[1]
     
    sensor elementquartz  
     
    Geometry of the sensor elementshear principle  
     
    housing materialtitanium  
     
    SealingHermetically sealed welded  
     
    Electrical connection5-44 coaxial  
     
    connection positionabove  
     
    Mounting thread5-40 male  
     
    Assembly torque8 … 12 in-lb90 … 135 NCM 
    notes
    [1]Typically  
     
    [2]zero-based balancing line, determined using the method of least squares  
     
    [3]Transverse acceleration sensitivitytypically ≤ 3%  
     
    [4]details: see PCBs Declaration of conformance PS023  
    equipment
    080A109Mount wax-1 
     
    080A15adhesive mounting-1 
     
    ACS-1frequency response, r ückführbar on NIST (10 Hz up to the upper 5% point)-1 
    (A) glue Assembly
    Accessories   
     
    080A90Glue-1 
    (M) metric mounting
    mounting threadM3 x 0.50 male  
     
    equipment   
     
    M080A15adhesive mounting-1 
    (Q) increased discharge charge time constant
    frequency range (±5%)0.15 … 10,000 Hz  
     
    Frequency range (± 10%)0.1 … 20,000 Hz  
     
    discharging charging time constant?  
     
    Settling<  
     
    equipment   
     
    ACS-97Low frequency calibration of 1 … 10 Hz-1 
    (B) reduced bias voltage
    Bias voltage4.5 … 7.5 V DC  
     
    Power12 … 30 V DC  
     
    constant power supply1 … 20 mA  
     
    Measuring range300 g pk2.943 m/s² pk 
    (J) Mass insulation
    frequency range (±5%)1 … 8,000 Hz  
     
    frequency range (± 10%)0.7 … 15,000 Hz  
     
    Resonance frequency56,000 Hz  
     
    electrical insulation≥100 MΩ  
     
    size - hex3/8 in9.5 mm 
     
    Size - height0.76 in19.3 mm 
     
    mass0.09 oz2.7 grams 
    (W) waterproof cable
    Connecting positiontop  

    21 other articles of the same category: