PCB-352C23/NC
- ICP®-miniature vibration sensor,
- Mass 0.2 grams.
- Mass-insulated,.
- Measuring range 1000 g,
- Sensitivity 5 mV / g,.
- Frequency range 2... 10,000 Hz,
- 3-56 female connector on the side.
- Without cable
| Basic data | |||
| Sensitivity (±20 %) | 5 mV / g | 0.5 mV/(m/s²) | |
| Measuring range | ±1.000 gPK | ±9.810 m/s²PK | |
| Frequency range (≤5 %) | 2.0... 10,000 Hz | ||
| Frequency range (±10 %) | 1.5... 15,000 Hz | ||
| Frequency range (± 3 dB) | 0.7... 25,000 Hz | ||
| Resonance frequency | ≥70.000 Hz | ||
| Wide band resolution | 0.003 g RMS | 0.03 m/s² RMS | [2] |
| Linearity error | ≤1 % | [1] | |
| Transverse acceleration sensitivity | ≤5 % | ||
| Conditions of use | |||
| Overload limit (shock) | ±10.000 gPK | ±98.000 m/s²PK | |
| temperature range (operation) | -65... 250 ° F | -54... 121 ° C | |
| specifications | |||
| power supply | 18... 30 V DC | ||
| constant power supply | 2... 20 mA | ||
| output impedance | ≤200 Ω | ||
| Bias voltage | 7... 11 V DC | ||
| discharging charging time constant | 0.24... 1,0 s | ||
| settling time (auf Bias-Spannung ±10 %) | >3 s | ||
| spectral noise (1 Hz) | 1,500 µg/√Hz | 14.715 (µm/s²)/√Hz | [2] |
| spectral noise (10 Hz) | 400 µg/√Hz | 3,924 (µm/s²)/√Hz | [2] |
| spectral noise (100 Hz) | 120 µg/√Hz | 1,177 (µm/s²)/√Hz | [2] |
| spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm/s²)/√Hz | [2] |
| Spectral noise (10,000 Hz) | 20 µg/√Hz | 196 (µm/s²)/√Hz | [2] |
| electrical insulation (base) | ≥ 100 MΩ | ||
| -physical Properties | |||
| size - height | 0.11 in | 2.8 mm | |
| size - length | 0.34 in | 8.6 mm | |
| size - width | 0.16 in | 4.1 mm | |
| mass | 0.007 oz | 0.2 grams | [2] |
| sensor element | ceramic | ||
| geometry of the Sensor element | shear principle | ||
| housing material | anodized aluminum | ||
| waterproofing | epoxy resin | ||
| Electrical connection | 3-56 coaxial plug | ||
| connection position | side | ||
| mounting | Adhesive mounting | ||
| Notes | |||
| [1] | Zero-balance just, determined using the method of least squares | ||
| [2] | Typically | ||
| [3] | Details: see PCBs Declaration of conformance PS023 | ||
| Included accessories | |||
| 039A26 | Transfer tool | -1 | |
| 080A109 | Mount wax | -1 | |
| ACS-1 | Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt) | -1 |