PCB-352C22/NC
- ICP®-miniature vibration sensor, li >
- Mass 0.5 grams.
- Mass-insulated,.
- Measuring range 500 g
- Sensitivity 10 mV / g,.
- Frequency range 1... 10,000 Hz,
- 3-56 female connector on the side.
- Without cable
| Basic data | |||
| Sensitivity (± ≤5 %) | 10 mV / g | 1.0 mV/(m/s²) | |
| Measuring range | ±500 gPK | ±4.900 m/s²PK | |
| Frequency range (≤5 %) | 1.0... 10,000 Hz | ||
| Frequency range (±10 %) | 0.7... 13,000 Hz | ||
| Frequency range (± 3 dB) | 0.3... 20,000 Hz | ||
| Resonance frequency | ≥50.000 Hz | ||
| Wide band resolution | 0.004 g RMS | 0.04 m/s² RMS | [2] |
| Linearity error | ≤1 % | [1] | |
| Transverse acceleration sensitivity | ≤5 % | ||
| Conditions of use | |||
| Overload limit (shock) | ±10.000 gPK | ±98.000 m/s²PK | |
| temperature range (operation) | -65... 250 ° F | -54... 121 ° C | |
| specifications | |||
| power supply | 18... 30 V DC | ||
| constant power supply | 2... 20 mA | ||
| output impedance | ≤300Ω | ||
| Bias voltage | 7... 11 V DC | ||
| discharging charging time constant | 1.0... 3<5 s | ||
| settling time (auf Bias-Spannung ±10 %) | < 3s | ||
| spectral noise (1 Hz) | 800 µg/√Hz | 7.840 (µm/s²)/√Hz | [2] |
| spectral noise (10 Hz) | 250 µg/√Hz | 2,450 (µm/s²)/√Hz | [2] |
| spectral noise (100 Hz) | 60 µg/√Hz | 590 (µm/s²)/√Hz | [2] |
| Spectral noise (1,000 Hz) | 50 µg/√Hz | 490 (µm/s²)/√Hz | [2] |
| Spectral noise (10,000 Hz) | 40 µg/√Hz | 392 (µm/s²)/√Hz | [2] |
| electrical insulation (base) | ≥ 100 MΩ | ||
| physical properties | |||
| Size - height | 0.14 in | 3.6 mm | |
| size - length | 0.45 in | 11.4 mm | |
| size - width | 0.25 in | 6.4 mm | |
| Mass | 0.017 oz | 0.5 grams | [2] |
| sensor element | ceramic | ||
| geometry of the sensor element | Shear principle | ||
| housing material | anodized aluminum | ||
| waterproofing | epoxy resin | ||
| Electrical connection | 3-56 coaxial plug | ||
| Connecting position | side | ||
| attachment | bonding | ||
| notes | |||
| [1] | Zero-balance just, determined using the method of least squares | ||
| [2] | Typically | ||
| [3] | Details: see PCBs Declaration of conformance PS023 | ||
| Included accessories | |||
| 039A27 | Transfer tool for models 352 C 22, 357 C-10, 352A21 and 357A09 | -1 | |
| 080A109 | Mount wax | -1 | |
| ACS-1 | Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt) | -1 |