PCB-352A73

PCB-352A73

  • ICP®-miniature vibration sensor,
  • Mass 0.2 grams,
  • Measuring range 1000 g,
  • Sensitivity 5 mV / g,
  • Frequency range 2 … 10,000 Hz,
  • Integrated cable, length 3 m,
    ending on 10-32 plug
  • basic data
    sensitivity (±20%)5 mV / g0.51 mV/(m/s²)
    range± 1.000 g pk ±9. 810 m/s² pk
    frequency range (±5%)2.0 … 10,000 Hz
    Frequency range (± 10%)1.5 … 25,000 Hz
    frequency range (± 3 dB)0.7 … 40,000 Hz
    Resonance frequency≥ 70,000 Hz
    wide band resolution0.002 g RMS0.02 m/s² RMS[1]
    Linearity≤ 1%[2]
    transverse acceleration sensitivity≤ 5%
    conditions of use
    (Shock) overload limit± 10.000 g pk±98. 000 m/s² pk
    Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
    Specifications
    power supply18 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤200Ω
    Bias voltage7 … 11 V DC
    Discharging charging time constant0.2 … 1,0 s
    settlingbr(auf Bias-Spannung ±10 %)< 3 s
    Spectral noise (1 Hz)875 µg / √ Hz8.580 (µm / s ²) / √ Hz[1]
    spectral noise (10 Hz)150 µg / √ Hz1.470 ( µm / s ²) / √ Hz[1]
    spectral noise (100 Hz)45 µg / √ Hz440 (µm / s ²) / √ Hz[1]
    spectral noise ( 1,000 Hz)20 µg / √ Hz196 (µm / s ²) / √ Hz[1]
    spectral noise ?10.000 Hz)10 µg / √ Hz98 (µm / s ²) / √ Hz[1]
    physical properties
    size - height0.11 in2.8 mm
    Size - length0.34 in8.6 mm
    size - width0.16 in4.1 mm
    dimensions (without cable)0.01 Oz0.3 grams[1]
    sensor elementceramic
    geometry of the sensor elementshear principle
    Housing materialtitanium
    sealinghermetically sealed
    wiringangelö pins coated cable
    cable exitside
    cable terminating resistance10-32-coaxial connector
    Cable length10 ft3 m[3]
    Attachmentbonding
    notes
    [1]typically
    [2]zero-based balancing line, determined using the method of least squares
    [3]composed of 30 cm cable type 089 (32 AWG, twisted pair) and 2.7 m coaxial cable type 018
    equipment
    039A26Transfer tool-1
    080A109mounting wax-1
    ACS-1frequency response, Rü ckführbar on NIST (10 Hz up to the upper 5% point)-1

    20 other articles of the same category: