PCB-(M)602D91

PCB-(M)602D91

  • Industrial ICP® vibration sensor,
  • With through hole,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5 … 8,000 Hz,
  • One-point calibration at 100 Hz,
  • M12 connector on the side
  • "
    basic data
    sensitivity (±10%)100 mV/g10.2 mV/(m/s²)[1]
    measuring range±50 g±490 m / s²
    Frequency range (± 3 dB)30 … 480,000 cpm0.5 … 8,000 Hz[4]
    resonance frequency1,500 kcpm25,000 Hz[2]
    Wide band resolution350 µg3.434 µm / s ²[2]
    linearity≤1%[3]
    Transverse acceleration sensitivity≤ 7%
    conditions of use
    (shock) overload limit49,050 m/s ² pkpk 5,000 g
    Temperature range-65 … 250 ° F-54 … 121 ° C
    temperature impact on Temperature coefficient of sensitivitysee curve below[2]
    Protection classIP68
    technical characteristics
    settling time (on area within ±1% of the bias voltage)≤ 3.0 s
    Discharging charging time constant≥ 0.3s
    power18 … 28 V DC
    constant power supply2 … 20 mA
    output impedance< 150 Ω
    Bias voltage8 … 12V DC
    Spectral noise (10 Hz)8.0 µg / √ Hz78.5 (µm / s ²) / √ Hz[2]
    spectral noise (100 Hz)5 µg / √ Hz49,1 (µm / s ²) / √ Hz[2]
    spectral noise (1,000 Hz)4 µg / √ Hz39.2 (µm / s ²) / √ Hz[2]
    Electrical insulation≥ 100 MΩ
    physical properties
    size - length1.55 in39.4 mm
    Size - width0.74 in18.8 mm
    Size - height0,845 in21.5 mm
    mass2.61 oz74.0 grams
    Mounting thread1/4 "-28 threadNo metric equivalent[5]
    Assembly torque2 … 5 ft-lb2.7 … 6.8 Nm
    Sensor elementceramic
    geometry of the sensor elementshear principle
    housing materialStainless steel (316 L)
    Sealinghermetically sealed welded
    connectionon the side
    notes
    [1]conversion factor 1 g = 9.81 m/s²
    [2]typically
    [3]zero-based balancing line,. determined with the method of least squares
    [4]the upper cut-off frequency tolerance: ±10%
    [5]no equivalent in SI
    [6]details: see PCBs Declaration of conformance PS023
    equipment
    081A97 Transit bolt 1 /.4 ' 28-1
    ICS-2single point calibration at 100 Hz (traceable to NIST)-1
    (M) metric mounting
    supplied accessories " ör
    M081A97metric mounting bolt with M6 thread-1

    29 other articles of the same category: